Operating Conditions
DPM III xi series
14
Operating manual
04.18
Power line voltage and power line frequency: See type plate
Allowable tolerance of power line voltage:
+6%
…−10% of nominal value
Allowable tolerance of power line frequency:
+2%
…−2% of nominal value
Allowable distortion factor of power line voltage: <=5%
In case your net is infected (e.g. by using thyristor controlled
machines) anti-interference measures have to be taken. It is possible
to use one of the following possibilities:
Provide separate power supply to our direct print modules.
In case of problems please connect capacity-decoupled isolation
transformer or similar interference suppressor in front of our direct
print modules.
Emitted interference according to EN 55022
Interference voltage to wires according to EN 55022:2011-04
Interference field power according to EN 55022:2011-04
System perturbation according to EN 61000-3-2:2010-03
Flicker according to EN 61000-3-3:2014-03
Immunity according to EN 61000-6-2:2011-06
Stray radiation against discharge of static electricity according to
EN 61000-4-2:2009-12
Electromagnetic fields according to EN 61000-4-3:2011-04
Fast transient burst according to EN 61000-4-4:2013-04
Surge according to EN 61000-4-5:2007-06
High-frequency tension according to EN 61000-4-6:2009-12
Voltage interruption and voltage drop according to EN 61000-4-
11:2005-02
NOTICE!
This is a machine of type A. This machine can cause
interferences in residential areas; in this case it can be
required from operator to accomplish appropriate measures
and be responsible for it.
EN 60950-1: 2006 - Safety of pachaging machines
EN 60204-1: 2006 - Safety of machinery - Electrical equipment of
machines - Part 1
Technical data of
power supply
Anti-interference
measures
Stray radiation and
immunity from
disturbance
Machine safety
Содержание DPM III XI
Страница 1: ......
Страница 8: ......
Страница 22: ...Technical Data DPM III xi series 22 Operating manual 04 18 Example 1 Example 2 Example 3 ...
Страница 34: ......
Страница 38: ......
Страница 62: ......
Страница 72: ...Signal Diagrams DPM III xi series 72 Operating manual 04 18 10 2 Mode 2 continuous mode ...
Страница 84: ......
Страница 90: ......
Страница 92: ......
Страница 95: ......
Страница 96: ......