1.0   PRODUCT PRESENTATION

The CARINCI EVOLUTION Thermo Fireplace is built to satisfy the needs of the customer. Its design allows the placement 

in any environment. The innovation of our product is in the technical enhancements, which provide an efficiency like 

no other.
The 

CARINCI

 Thermo Fireplace, in fact, has been designed as a real boiler for sanitary hot water production and as 

a heating appliance.
The boiler, inside which the water (thermo courier fluid) circulates, uses special exchangers located within
the combustion chamber, easy to inspect for their cleaning.
These exchangers ensure proper circulation of thermo courier fluid even at very high temperatures, eliminating the bother 

of the boiling noise and ensuring the maximum safety of the user in any condition, even during a temporary lack of power.
The efficiency is optimized by the presence of an “air restrictor” located in the upper-front of the Thermo Fireplace-boiler that 

allows the entrance of premixed air, giving rise to a steady and homogeneous flame. Also the base of the Thermo Fireplace-

boiler affects the yield being made of refractory (fire-resistant) bricks 1350°C vertically positioned with 11 cm thickness 

gauge, allowing it to maintain a constant temperature.

Содержание evolution

Страница 1: ......

Страница 2: ...0 Installation of the Thermo Fireplace CARINCI EVOLUTION pag 18 6 1 Open vented simple installation diagram pag 18 6 2 Expansion vessel pag 19 6 3 Sanitary hot water pag 19 6 4 Process control and sh...

Страница 3: ...ag 30 10 0 Recommendations for use pag 31 10 1 Using the Thermo Fireplace CARINCI EVOLUTION in adverse weather conditions pag 31 10 2 Door opening pag 31 10 3 Use of the Thermo Fireplace CARINCI EVOLU...

Страница 4: ...appliance b Do not use the appliance as an incinerator or in any way other than for its intended purposes c Do not use fuels other than the ones recommended d Do not use liquid fuels e When operating...

Страница 5: ...angers located within the combustion chamber easy to inspect for their cleaning These exchangers ensure proper circulation of thermo courier fluid even at very high temperatures eliminating the bother...

Страница 6: ...NS AND DIMENSIONS 1087 334 1219 589 250 269 768 269 950 557 533 522 880 950 632 533 280 667 1090 380 710 950 280 250 THERMO FIREPLACE CARINCI EVOLUTION Mod 150 FRONT VIEW AND SIDE VIEW THERMO FIREPLAC...

Страница 7: ...0 278 990 950 278 742 533 777 990 490 965 590 110 950 278 250 887 1100 852 533 1100 278 THERMO FIREPLACE CARINCI EVOLUTION Mod 250 FRONT VIEW AND SIDE VIEW THERMO FIREPLACE CARINCI EVOLUTION Mod 300 F...

Страница 8: ...Temperature 1620 C Apparent porosity 18 20 Weight Volume 1850 1950 Kg mc Compressive strength cold 300 350 Kg mc Compressive strength hot 1210 C Ta Tr Temporary expansion 0 65 1000 C Permanent linear...

Страница 9: ...lt a qualified technician c It is recommended to install the thermo fireplace from floor to fire level of about 40 50 cm height to simplify the use d Form a straight line surface by using the appropri...

Страница 10: ...rea b roof at 15 0 50 m over the ridge distance 1 85 m distance 1 85 m 1 m minimum reflux area TECHNICAL VOLUME a flat roof distance 5 m distance 5 m 3 0 FLUE in compliance with Regulation UNI cig 712...

Страница 11: ...than the peak of the roof g If required an incline is allowed but no higher than 45 for variations of sections or parts the functioning of the fumes evacuation system must be inspected with a suitabl...

Страница 12: ...ack must comply with the following requirements a Have the same diameter of the flue b Be well isolated c Be located in the highest point d Guarantee the correct dispersion of fumes in any weather con...

Страница 13: ...ar a staircase to the upper floors it is necessary to close it off with a hermetic door Note it is strictly forbidden to create the air scoop below thermo fireplace hood in order to avoid boiler body...

Страница 14: ...tion the expansion vessel in the highest point of the house b There is no need to break walls or attics to allow the passage of the piping c Easy installation d Less time required for the installation...

Страница 15: ...xed Cold water inlet Cold water inlet Heating system flow Heating system flow Heating system return Heating system return load pipe expansion tank load pipe expansion tank load pipe thermo fireplace l...

Страница 16: ...Heating return copper pipe of appropriate section but not less than 28 mm diameter 10 Circulator we recommend positioning the circulator not adhering to the thermo fireplace but in adequate posi tion...

Страница 17: ...water outlet pipe of the thermo fireplace Furthermore in the case where the sanitary exchanger is not used it should be left open without any kind of cap some insulating tape can be applied in order t...

Страница 18: ...TALLATION COMBINED WITH A GAS BOILER Equipped with expansion vessel and safety discharge valve For SYSTEM and IDROKIT If the existing heating system has a gas boiler fitted with expansion vessel and s...

Страница 19: ...RINCI SYSTEM COMBINED WITH A GAS BOILER figure B motorized valve non return valve boiler return boiler flow BOILER Heating system flow Heating system return output overflow pipe Domestic hot water out...

Страница 20: ...M TC R TC M IMP CS 8 Domestic hot water outlet mixed Load pipe Safety pipe open expansion vessel Input water system Input thermo fireplace water boiler domestic water inlet gas boiler Heating system...

Страница 21: ...place the overflow pipe exit in the external wall at a man height c It must be channelled into a waste water catch basin whose end must be easily inspectable in case of any small loss due to breakage...

Страница 22: ...LVE C A 05 20 42 85 INSTALLER Menu The access to this menu is LIMITED TO TECHNICIANS OR TRAINED PERSONNEL since some parameters if modified can make the product no longer suitable for the application...

Страница 23: ...in STANDBY 6 Function TEST PUMP 1 By pressing and holding P2 button PUMP output will be activated for as long as the button is pressed The display will show tSt 7 ACQUAPLUS function Through the simpl...

Страница 24: ...A 06 20 50 85 INSTALLER Menu The access to this menu is LIMITED TO TECHNICIANS OR TRAINED PERSONNEL since some parameters if modified can make the product not anymore suitable for the application in...

Страница 25: ...n Through the simple click of P1 MENU button PUMP output will be deactivated until the SAFETY A02 temperature of 85 C is reached after reaching this temperature PUMP output will be activated until rea...

Страница 26: ...cilitate the initial combustion Doing it this way the time needed for the condensation in the combustion chamber will be shortened and the formation of excessive encrustation tar will be avoided e Onc...

Страница 27: ...to the collector through the adjustment screw of the flux valve in order to avoid the annoyance of dripping and improve the inflow of water in radiators furthest thus improving their efficiency c In c...

Страница 28: ...ngs decreasing the inlet air and thus slowing down the combustion d If the flame is too weak screw using the hexagonal key in order to widen the air throttler rings increasing the inlet air and thus i...

Страница 29: ...s the air inlet c Check the right amount of combustive secondary air d Put back the side covering 8 4 SECONDARY AIR The secondary air improves combustion in the upper part of the combustion chamber Fo...

Страница 30: ...reen air 1 3 open Test Duration 45 min 45 min 9 0 COVERING The thermo fireplace CARINCI must be fully upholstered except only for the glass shutter Any maintenance of the sliding can be performed with...

Страница 31: ...remove the wood from the combustion chamber of the thermo fireplace c Remove the ash with the specific ash shovel d Air the room 10 5 OVERHEATING Should the thermo fireplace reach high temperatures u...

Страница 32: ...ur product 12 1 HEAT EXCHANGERS CLEANING At least twice a year the inside of the combustion chamber should be cleaned following these easy steps a Open the shutter door of the thermo fireplace b Unscr...

Страница 33: ...thermo fireplace scraper d Once the cleaning is completed put back the cast iron plate rescrewing the two screws removed beforehand CAUTION For your personal safety before proceeding with the cleaning...

Страница 34: ...ou may experience a few unpleasant events that require extraordinary maintenance Here is some advice but we always recommend to contact our customer service office tel no 39 0776 812704 or technical a...

Страница 35: ...e A b Raise the counterweight c Take the counterweight raised with a support made of wood or similar to facilitate the re alignment of the chain on the pinion see figure B d Insert a hand inside the d...

Страница 36: ...Probe junction Female junction 1 2 5 6 Hot sanitary water outlet Male junction 3 4 6 5 Hot sanitary water inlet Male junction 3 4 7 Filling pipe System Female junction 1 1 4 Model A B C D E F G H I L...

Страница 37: ...1 g s 22 1 g s 23 g s 20 1 g s 21 1 g s 22 1 g s 23 g s Sanitary Maximum Water Pressure 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar 3 5 bar...

Страница 38: ...38 38...

Страница 39: ...39...

Страница 40: ...e paintwork or other alterations that occur due to normal use and high temperatures k For defects or malfunctions caused by inadequate drafts from the chimney stack installation of an incorrect chimne...

Страница 41: ...Y FOR THE FIRST TIME The T A C only when authorised in advance by CARINCI GROUP S p A can perform the Set Up procedure Name Surname Address Postcode City Province Tel CARINCI MACHINERY Mod Matriculati...

Страница 42: ...i Damage caused by an inadequate electrical system whose grounding does not comply j For variations in colour scratches to the paintwork or other alterations that occur due to normal use and high temp...

Страница 43: ...2016 Carinci Group S p A Reproduction also partial is forbidden I ed January 2016...

Страница 44: ......

Отзывы: