EVOLUTION G
EVOLUTION R
150
200
250
300
SYSTEM
150
200
250
300
SYSTEM
150
200
250
300
150
200
250
300
Thermal Power
25,1
kW
28
kW
31
kW
34.2
kW
25.1
kW
28
kW
31
kW
34.2
kW
24.6
kW
28
kW
31
kW
34.2
kW
24.6
kW
28
kW
31
kW
34.2
kW
Thermal Power
Nominal
20.5
kW
23
kW
26
kW
28.5
kW
20.5
kW
23
kW
26
kW
28.5
kW
20
kW
23
kW
26
kW
29
kW
20
kW
23
kW
26
kW
29
kW
Heating Power
Performance
(environment)
5 kW
6.5
kW
8.5
kW
10
kW
5 kW
6.5
kW
8.5
kW
10
kW
8 kW
9 kW
9.5
kW
10
kW
8 kW
9 kW
9.5
kW
10
kW
Heating Power
on water
15.5
kW
16.5
kW
17.5
kW
18.5
kW
15.5
kW
16.5
kW
17.5
kW
18.5
kW
12
kW
14
kW
16.5
kW
19
kW
12
kW
14
kW
16.5
kW
19
kW
Yield
83%
83.5%
83.5%
84%
83%
83.5%
83.5%
84%
83%
83.5%
84.5%
85.5%
83%
83.5%
84.5%
85.5%
CO measured
at 13% O
2
0.13%
0.13%
0.15%
0.15%
0.13%
0.13%
0.15%
0.15%
0.09%
0.09%
0.14%
0.14%
0.09%
0.09%
0.14%
0.14%
Temperature of
exhaust gas
201
°C
201
°C
176
°C
176
°C
201
°C
201
°C
176
°C
176
°C
199
°C
199
°C
194
°C
194
°C
199
°C
199
°C
194
°C
194
°C
Fireplace
minimum draft
requirements
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
12 ±
2 Pa
Combustion gas
volumetric
flux
19,3
g/s
22,4
g/s
25,5
g/s
28,6
g/s
19,3
g/s
22,4
g/s
25,5
g/s
28,6
g/s
20,1
g/s
21,1
g/s
22,1
g/s
23
g/s
20.1
g/s
21.1
g/s
22.1
g/s
23
g/s
Sanitary
Maximum
Water Pressure
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
3,5
bar
Sanitary
Maximum
Water Pressure
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
1,5
bar
Boiler
Contained Water
69 lt
82 lt
95 lt
111 lt
69 lt
82 lt
95 lt
111 lt
69 lt
82 lt
95 lt
111 lt
69 lt
82 lt
95 lt
111 lt
Convective air
inlet minimum
section
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
Convective air
outlet minimum
section
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
300 x
200
mm
Mass
of the Appliance
285
kg
325
kg
365
kg
405
kg
310
kg
350
kg
390
kg
430
kg
285
kg
325
kg
365
kg
405
kg
310
kg
350
kg
390
kg
430
kg
Fumes junction
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
250
mm
Flammable
materials minimum
security distance
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm
200
mm