“ultimateSAM - user” +0300070IE - rel. 1.0 - 23.05.2013
A complete list of available kits, as well as information on other features,
is provided in Tab.3.b.
2
4
3
5
6
SAK
T
x x
x
x 0
x
1
ID prefi x
Material:
F =
S =
Iron
SS
Type:
S =
T =
Condensate separator
Trap & strainer assembly
Size:
15 =
20 =
25 =
32 =
40 =
44=
50=
65=
84=
DN 15 fl ange
DN 20 fl ange
DN 25 fl ange
DN 32 fl ange
DN 40 fl ange
1” pipe thread
DN 50 fl ange
DN 65 fl ange
2” pipe thread
Region:
U =
0 =
North America
Other
---
---
Tab. 3.a
Table 3.b provides a complete listing of all of the traps, strainers, and
other accessories available for the use with the ultimateSAM distributor.
In addition, the table provides information on the size and type of inlet-
outlet connection for each accessory.
Inlet-Outlet Connections
Material, Type, Region Codes
Size
“****FT**0*
****FS**0*
****FT**U*
****ST**U*
SAKT**15*0
Flange DN 15
n/a
n/a
SAKT**20*0
Flange DN 20
n/a
n/a
SAKT**25*0
Flange DN 25
n/a
n/a
SAKT**32*0
Flange DN 32
n/a
n/a
SAKT**40*0
Flange DN 40
n/a
n/a
SAKT**44*0
n/a
1” NPT Female
1”NPT Female
SAKT**50*0
Flange DN 50
n/a
n/a
SAKT**65*0
Flange DN 65
n/a
n/a
SAKT**84*0
n/a
2” NPT Female
2” NPT Female
Tab. 3.b
Before installing an optional fl anged trap and strainer kit, be sure that
the fl ange size matches the fl ange on the control valve. For an optional
threaded trap and strainer kit, be sure that the kit is properly sized for the
control valve. (Refer to the design manual for more information.)
Table 3.c lists the items and quantity of threaded fi ttings that are included
in each threaded trap and strainer kit. Flanged trap and strainer kits are
fully integrated. See Figure 3.c, and section 9, Figure 9.x -Trap, strainer, and
separator kits for more details.
Item List for SAKT*T**U0
Item (NPT)
SAKT*T44*0
SAKT*T84*0
Y-type stainer
1 (1”)
1 (1”)
F&T trap
1 (¾”)
1 (¾”)
Bushing F-M (size)
1 (¾”x1”)
1 (¾”x2”)
Elbow F-M (size)
1 (¾”)
1 (¾”)
Elbow F-F (size)
1 (1”)
1 (2”)
Nipple M-M (size)
2 (¾”x6”)
1 (1”x3”)
1 (1”x6”)
2 (¾”x6”)
1 (2”x3”)
1 (2”x6”)
Tee F-F-F (size)
1 (1”)
1 (2”)
Union F-F (size)
1 (¾”x¾”)
1 (¾”x¾”)
Tab. 3.c
3.3 Inlet drains for distributors connected
to atmospheric steam supplies
When used with an atmospheric humidifi er, as shown in (Fig.3.e and Fig.
3.f ), an inlet trap may not be needed on the ultimateSAM distributor. In
a typical installation, the condensate in the connecting hose drains back
to the humidifi er. In special situations when the condensate cannot drain
back to the humidifi er, an inlet trap may be needed to prevent signifi cant
amounts of condensate from entering the distributor.
Fig. 3.i
20
°
mi
n
.
Fig. 3.j
Nota:
The adapters and steam hoses shown above are available
as options. The “P” drains are not provided as part of the
ultimateSAM system.