Cardinal 2XX-IP Скачать руководство пользователя страница 9

8200-M503-01 Rev-B 

 2XX-IP 

7

225 INDICATOR SETUP 

With the indicator ON, hold the 

SHIFT

 key down and press the Navigation 

ENTER

 key (red 

square key in center of the Navigation arrows).  The display will change to show the 
SETUP/REVIEW MENU. 
 

SETUP/REVIEW MENU 

1.ENTER CALIBRATION AND SETUP 

2.VIEW AUDIT TRAIL COUNTERS 
3.CALIBRATE SCALE 1 
                              9.DEL CUSTOM TICKET 
                           

 

10.PRINT SETUP 

Enter Selection: 1 

 

EXIT 

 
Press the 

ENTER

 key, then press the 

NEXT

 Navigation arrow until SETUP MENU #3 is 

displayed. 
 

SETUP MENU #3 

1. G/N ACCUMS=XXX     6.  KEY LOCKOUT 

2. BACK LITE= X        

 

7.  LRPort=COM3 

3. PASSWORD 
4. 2XX-IP 
5. BADGE RDR 
Enter Selection:  0  

PREV  

EXIT 

 
Press the 

key and then the 

ENTER

 key, the 2XX-IP SETUP MENU will be displayed. 

 

2XX-IP SETUP MENU 

1. CONT=XXX 

 

2. TYPE=X XXXXXXXXX
3. SCALE = 0 

 

 
 
Enter Selection:  0    

EXIT 

 
 

1. CONT=XXX 

To turn the continuous data output 

ON

 or 

OFF

, press the 

1

 key and then the 

ENTER

 key. 

 

2XX-IP SETUP MENU

 

 
 
 
 
CONT=XXX 
   YES                                             NO 

 
Press the 

YES

 and 

ENTER

 keys to turn continuous data output 

ON

 or press the 

NO

 and 

ENTER

 keys to turn it off. 

 

Содержание 2XX-IP

Страница 1: ...For 200 Series Indicators 205 210 212G 212GX and 225 INSTALLATION MANUAL 8200 M503 O1 Rev B 203 E Daugherty Webb City MO 64870 USA Printed in USA 10 14 Ph 417 673 4631 Fax 417 673 2153 http www cardin...

Страница 2: ...8200 M503 01 Rev B 2XX IP 2...

Страница 3: ...are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case...

Страница 4: ...nt panel to the rear housing 4 Separate the rear panel from the front housing on the 205 210 and 225 or the front panel from the rear housing on the 212G 212GX 5 Lift the panel from the main housing t...

Страница 5: ...P Option Card Cont 205 210 212G 212GX Main PCB NOTE 205 Main PCB shown The 210 212G 212GX Main PCB will have connector P2 REMOTE OUTPUTS and J7 REMOTE OUTPUT SRC jumper installed 225 Main PCB P15 OPTI...

Страница 6: ...nut and remove the plastic insert 5 Route the Ethernet cable CAT 5 or equivalent through the nut and plastic insert and into the enclosure 6 With the Ethernet cable routed into the enclosure refer to...

Страница 7: ...OLS Finger tighten only Insure any unused gland connectors are plugged 2 Make certain no cables or wires are exposed between the main housing and rear panel 3 Place the rear panel onto the main housin...

Страница 8: ...Output No Continuous Output If Cont4 YES Continuous Output is selected an additional prompt tYPE4 will be displayed If Cont4 no No Continuous Output is selected the indicator will operate in the Weig...

Страница 9: ...key then press the NEXT Navigation arrow until SETUP MENU 3 is displayed SETUP MENU 3 1 G N ACCUMS XXX 6 KEY LOCKOUT 2 BACK LITE X 7 LRPort COM3 3 PASSWORD 4 2XX IP 5 BADGE RDR Enter Selection 0 PREV...

Страница 10: ...e 2XX IP card can be selected Press the 7 key and then the ENTER key 2XX IP SETUP MENU SCALE XXX Allowable values are 0 through 5 NOTE Scale 1 is the default setting Also note 4 is the Scale Totalizer...

Страница 11: ...LED is not flashing then communications between the 2XX IP and the indicator has failed XPORT Status LED s LED s are provided on the edge of the XPORT connector for diagnostics Their status and meani...

Страница 12: ...8200 M503 01 Rev B 2XX IP 10...

Отзывы: