8200-M503-01 Rev-B
•
2XX-IP
6
205/210/212G/212GX INDICATOR SETUP
A new section has been added to the SETUP menu for the 2XX-IP board. The new sub menu
Option
(Option) has been placed after
LoCoUT
(Key Lock Out Function). The
Option
sub
menu contains the setup required to establish communications.
NOTE:
The prompt will display as
Option
when using the CAL switch and
Opt?
when using
the
ENTER
key to advance through the setup prompts.
Cont4=
(Continuous Output Serial Port 4)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable,
press the
ENTER
key again to save it. Otherwise, use the numeric keys
0/NO
or
1/YES
(or
the arrow keys on the 205) to select a new setting and then press the
ENTER
key to save it.
Cont4= YES
Cont4= no
Continuous Output
No Continuous Output
If
Cont4= YES
(Continuous Output) is selected, an additional prompt,
tYPE4=
will be
displayed.
If
Cont4= no
(No Continuous Output) is selected, the indicator will operate in the Weight
on Demand mode (only output data in respond to a weight request, ENQ).
tyPE4=
(Continuous Output Format)
Press the
ENTER
key to show the current value. If the displayed setting is acceptable, press
the
ENTER
key again to save it. Otherwise, using the numeric keys (or the arrow keys on
the 205) enter the new setting, then press the
ENTER
key to save it. Allowable values are:
0 = SMA
1 = SB-400
2 = SB-200
3 = Rice Lake IQ355
4 = AnDFV
5 = WI110
6 = Number Only
7 = Toledo Long/Short
8 = SB500 with Traffic Light
9 = Ranger 5000 Format A
For a complete description of the Continuous Output and the Weight on Demand formats,
refer to the
SiO
Serial Input/Output section in manual 8200-M129-O1 for the 205, in manual
8200-M585-O1 for the 210 and in manual 8200-M694-O1 for the 212G/212GX.