8400-M022-O1 Rev K
Model 190 Indicator
18
d in=
X,Y (Digital Input)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to select the X, Y settings for the Digital Input, and press
the
TARE
key to save it.
where:
X = Input transition which activates selected keypad function
(0=open to closed, 1=closed to
open)
Y = Keypad function which will be performed
0 = Digital Input is disabled
1 =
ZERO
key function is performed when input goes from open to closed
2 =
key function is performed when input goes from open to closed
3 =
TARE
key function is performed when input goes from open to closed
4 =
NET/GROSS
key function is performed when input goes from open to closed
11 =
ZERO
key function is performed when input goes from closed to open
12 =
key function is performed when input goes from closed to open
13 =
TARE
key function is performed when input goes from closed to open
14 =
NET/GROSS
key function is performed when input goes from closed to open
d oUt=
X,Y (Digital Output)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to select the X, Y settings for the Digital Output, and press
the
TARE
key to save it.
where:
X = State below cutoff
(0=Output connected to common, 1=Output not connected to common)
Y = Preset Number or Checkweigher Mode
0 = Digital Output is disabled
1 = Output connected to common before cutoff with 1 active Preset
2 = Output connected to common before cutoff with 2 active Presets
3 = Output connected to common before cutoff with 3 active Presets
4 = Output connected to common before cutoff on Checkweigher Mode
11 = Output not connected to common before cutoff with 1 active Preset
12 = Output not connected to common before cutoff with 2 active Presets
13 = Output not connected to common before cutoff with 3 active Presets
14 = Output not connected to common before cutoff on Checkweigher Mode