8400-M022-O1 Rev K
Model 190 Indicator
98
Wiring
OUT 1 RED light
OUT 2 GREEN light
The PWC outputs will always function if the indicator is set for
d oUt=
5 and
AUto=YES
.
These outputs can be used, or the serial output of the indicator can contain the light state
information if continuous data type = 2 (
tYPE=
2, see below).
tyPE=
(Continuous Output Format)
Press the
TARE
key to show the current setting. If the setting displayed is acceptable,
press the
TARE
key again to save it.
Otherwise, use the
Fn/
key to toggle to a new setting and press the
TARE
key to save
it. Allowable settings are:
0 = Continuous Output uses SMA format
1 = Continuous Output uses Cardinal Scoreboard format
2 = Continuous Output uses Cardinal SB500 with traffic control format
NOTE:
Refer to the
CONT1=
Continuous Output on Serial Interface,
tYPE=
parameter
section for a description of output formats 0 and 1.
Cardinal SB500 with traffic control Continuous Output Format
If Cardinal SB500 with traffic control is selected, the data will be transmitted in the following
format:
%NDDDDDDDDDT<CR>
where:
N
= Panel number for a daisy chain configuration
D
= Byte of data to display at a respective location on the scoreboard
T
= Control character for the traffic light. Valid characters for T are:
=
G = Turn on the Green light
=
R = Turn on the Red light
=
" "(
space
) = no lights on
<CR> = Carriage Return