background image

12

      Part Number 3E1086 R2

September 2002

Set DIPSW1:7 to ON.

Present a Prox 125 card to the Prox Plus 125 reader.

Note:You must present the card within 30 seconds of setting DIPSW1:7 to ON. If

you are initialising with two readers connected to the URI, you should present
the card to the reader on URI plug P5.

Set DIPSW1:7 to OFF

The green LED (D44) will begin flashing continuously.

The other red LED (D10) will flash each time the URI replies to a poll from the
Commander.

Replace the lithium battery jumper (J1).

Restore the tamper by closing the door of the cabinet.

Approvals and Standards

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation.

If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

•

Reorient or relocate the receiving antenna.

•

Increase the separation between the equipment and receiver.

•

Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.

•

Consult the dealer or an experienced radio/TV technician for help.

Note:

Changes or modifications not expressly approved by Cardax (International)
Ltd could void the user's authority to operate the equipment.

Содержание Prox Plus 125

Страница 1: ...arthed before beginning anyservicing Before you Begin Unpack the Cardax Prox Plus 125 reader and check the shipment contains the following items 1 x Cardax Prox Plus 125 base with cable and Processor...

Страница 2: ...uce the read range of the Prox Plus 125 reader Cabling Use 4 core 0 2 mm2 AWG 24 cabling with a maximum nominal capacitance of 120 pf m The maximum external diameter of the cable must not exceed 5mm 1...

Страница 3: ...etween Proximity Readers The distance between any 2 proximity readers must be greater than 200mm in all directions Please note that 200mm in all directions includes the distance through walls Wall Pro...

Страница 4: ...o keep the unit waterproof Drill a 20mm 3 4 inch diameter hole for the base extrusion through or into the mounting surface to a minimum depth of 40mm 11 2 inch Run the building cabling through the bas...

Страница 5: ...towards the top of the reader with your thumb Lift the facia away from the base If the base is not flush to the wall or the screws have become loose you may need to pack the space between the de latch...

Страница 6: ...New Zealand Ltd REV A B C 22825V2 Assy 22826 5V 12V GND GND IN6 IN5 IN4 OUTPUTS OUTPUTS 5 12V 5 12V DET DET COMMS COMMS GND GND COM COM NO NO NC NC GND GND IN3 IN2 IN1 COMMS P4 Balanced Inputs pin 1 I...

Страница 7: ...his Installation Note for the location of the Cardax IV URI components Replacing the Facia Push the socket back into the grommet Push the connector into the socket and grommet combination Push the con...

Страница 8: ...itialise the URI with the door closed it sets the door to unlock and resets to lock as soon as the door is opened Push Button Exit If the door has a push button exit ensure the URI Exit terminal has t...

Страница 9: ...ow 3 4 Bottom Row 5 Left Column 6 Middle Column 7 Right Column 8 Not Used 1 Normally Open 2 Relay Common 3 Normally Closed Cardax Prox 125 Mifare or TIRIS Cardax Swipe 12 V ON OFF ON OFF Switch On Off...

Страница 10: ...ader Pins 1 2 4 and 5 reader type Exit Entry Connector J2 controls the Confirmed Entry function If you initialise the URI with no jumper fitted on J2 the Confirmed Entry function will be ON To switch...

Страница 11: ...For further details on software versions refer to Check Software Version in the InitialisationsectionearlierinthisInstallationNote CAUTION Do not fit the lithium battery jumper J1 before powering up t...

Страница 12: ...armfulinterferenceinaresidentialinstallation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful in...

Страница 13: ...Part Number 3E1086 R2 13 September 2002 Icons The Prox Plus 125 reader displays the following icons on the liquid crystal display LCD to indicate the access status of the zone controlled by the reader...

Отзывы: