Part Number 3E1086 R2
7
September 2002
Connecting to the Cardax IV URI
Connect the cables to the socket as shown.
Note: The colours shown in the diagram below are those used in the cable assembly
(Part No. 190810) which may be ordered already assembled.
Prox Plus 125 Connector
4
3
2
1
1
2
3
4
5
6
7
GND
BPR
LED
DET
1-CK
0-DT
5/12V
Plug P4 (Exit) or P5 (Entry)
Universal Reader Interface
Red
White
Blue
Black
Note: Refer to the Cardax IV URI Settings section, later in this Installation Note, for
the location of the Cardax IV URI components.
Replacing the Facia
Push the socket back into the grommet.
Push the connector into the socket and grommet combination.
Push the connector, socket and grommet back into the Prox Plus 125 base.
Firmly clip the interconnect PCB under the retaining clips in the base.
Fit the facia assembly onto the base by clipping the front over the top edge of the base and
pressing the bottom of the facia down un til it clicks into place.
Note: The pins on the interconnect PCB in the base of the Prox Plus 125 reader, fit
into the slots on the main PCB. The connector should be fitted to the base, not
the facia.