Carbine PLUS-4500 Скачать руководство пользователя страница 2

Index

Step 1: Component Installation 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-3

Step 2: 10-Pin Main Harness Installation 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3-4

Step 3: 5-Pin Power Harness Installation 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4-5

Step 4: DIP Switch Programming 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 Step 5

Optional Accessory Connections 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-11 Step 6

Transmitter Programming 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11-12 Step 7

Remote Feature Programming 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13-14 Step 8

General Testing 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15 Step 9

Speciality Feature and Optional Equipment Testing 

. . . . . . . . . . . . . . . . . . . . . . . .

15-18

Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

Wiring Diagrams 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Step 1: Component Installation

Mounting the Control Module:

Find a suitable location to secure the alarm control module within the passengers compartment of the

vehicle. Never mount the alarm control module in the engine compartment or in the trunk. In addition,

never mount the alarm control module in the direct path of the heater. Secure the alarm control module

by using wire ties or drill two 1/8” holes and secure the module to the frame of the vehicle with the

screws provided.

Mounting the Siren:

Find a suitable location in the engine compartment to secure the siren. Select a location that provides a

direct sound path to the ground for maximum siren output. Use the self tapping screws provided and

secure the siren. Connect the black wire coming from the siren to the frame of the vehicle. In many

cases, you can ground the black wire to one of the screws used to secure the siren. Run the remaining

brown wire through the fire wall to the location of the alarm control module.

Installing Hood/ Trunk Pin Switches:

Provided with the alarm kit is one pin switch and one mounting bracket. To install the switch either in the

truck or under the hood, find a suitable location where the switch will make contact with the hood or

trunk lid and will not get wet. Use the bracket provided or drill a 1/4” hole in the desired location.

2

Warning! Do not plug the 10-pin or 5-pin wire harness into the alarm control module before you begin

installing the alarm. The wire harnesses must be plugged into the alarm control module after all

connections are made. Failure to follow this procedure could cause some confusion with transmitter

operation and or alarm function operation.

The PLUS-4500 security system are packaged 2 different ways for maximum flexibility. Even though the

systems are packaged 2 different ways they all contain the same module and installation harnesses. The

following is how each model number is packaged:

PLUS-4500: 4500 Alarm Module with no transmitters and no siren.

PLUS-4500C: 4500 Alarm Module with (2) 4-button code-hopping transmitters and a siren.

Содержание PLUS-4500

Страница 1: ...pyright 2000 Magnadyne Corporation INSTALLATION MANUAL R Vehicle Security For Technical Assistance 800 638 3600 For Fax on Demand Technical Assistance 800 994 9977 Must be a Registered Dealer to Use F...

Страница 2: ...ct the black wire coming from the siren to the frame of the vehicle In many cases you can ground the black wire to one of the screws used to secure the siren Run the remaining brown wire through the f...

Страница 3: ...ires from the switch to the alarm control housing location Installing the Alarm Status LED The LED indicator provided utilizes a push in type mounting Drill a 5 16 hole in the desired location feed th...

Страница 4: ...ulsed Parking Light Relay Output Connect the red white wire to the parking light wire coming from the headlight switch Do not connect the red white wire to the dashboard lighting dimmer switch Damage...

Страница 5: ...ing 5 Step 3 5 Pin Power Harness Installation Continued Red Wire Main Power Input Connect the red wire directly to the battery post for best operation of the alarm system For best current sensing capa...

Страница 6: ...Lock Switch 87 87A 85 86 30 87 87A 85 86 30 To 12 Volts Battery Door Lock Compressor Cut Green Wire Black Wire Unlock Lock Unlock B Unlock Lock Red Wire Lock Orange Wire No Connection 3 Pin Black Plu...

Страница 7: ...k If a signal is received without a resistor the doors will lock Some use 2 resistors One for lock and one for unlock We have developed patented plug in fuse resistors for this application Simply remo...

Страница 8: ...ay pack E Plug in the orange 2 pin plug into the orange socket located at the rear of alarm module To test the dual circuit disable system refer to the starter disable testing procedures located in th...

Страница 9: ...de Switch with 2 Pin Blue Plug Dual Zone Electronic Sensor Plug Applies to PLUS 4000 Only Red Wire 12 Volt Sensor Power Supply Green Wire Sensor Pre Warning Output Black Wire Sensor Ground Supply Blue...

Страница 10: ...sert Red Wire into the First Socket Insert Black Wire into the Eighth Socket Black Wire 2 Button Power Trunk Activation Using Optional ALA RPT Relay Pack Dome Light Supervision Using Optional 30 Amp R...

Страница 11: ...Position S t e p 1 S t e p 2 ON S t e p 3 Turn On Ignition Switch the Valet Switch On then Off 1 Time The siren will stop sounding the parking lights will stop flashing S t e p 4 Switch the Valet Swi...

Страница 12: ...iren will emit 1 short chirp The code has now been learned The transmitters supplied are pre programmed to the receiver module You should use the following instructions when adding a new or replacemen...

Страница 13: ...f 3 Ignition Key Controlled Door Lock Unlock Off OFF ON OFF ON Make Sure the Valet Override Switch is in the Off Position S t e p 1 Switch in Off Position Switch in On Position Valet Override Switch S...

Страница 14: ...after door is closed and rearm 20 seconds after remote disarm 3 Beeps Automatic Arming On Alarm will arm 30 seconds after door is closed and rearm 60 seconds after remote disarm 4 Beeps Automatic Armi...

Страница 15: ...0 20 or 30 seconds have passed depending on remote feature programming you will hear a single chirp The alarm is now armed 6 The LED will flash at a regular rate indicating an armed condition Note Whe...

Страница 16: ...switch is in the off position 2 Turn the ignition key to the on position 3 Within 5 seconds of turning the ignition key place the valet switch to the on position 4 The LED will be on solid indicating...

Страница 17: ...passed Four chirps Tamper indicator alarm is disarmed Power Door Lock Unlock If Installed 1 Press the lock button on the transmitter the locks will become locked 2 Press the unlock button on the tran...

Страница 18: ...emote Feature Programming ignition controlled locking is active 3 seconds after the ignition key is set the on position the door locks will automatically become locked When the ignition key is turned...

Страница 19: ...Connection Dip Switches Black Wire Antenna Do Not Ground Power Door Lock Harness Socket Black Valet Override Socket Blue Black Wire Ground to Vehicle Frame Yellow Wire To Ignition Switched 12V Red Wir...

Страница 20: ...PLUS45IM 11 19 99 Rev F...

Отзывы: