background image

R

R

R

Code

Hopping

Regular

Lock

Unlock

Panic

Aux

Aux

Passive

Lock

Unlock

Panic

Aux

Unlock

Lock/

Panic

Step 7: Remote Feature Programming 

(Continued)

# Transmitter Button  Function

Confirmation = Change Function

1

LOCK

Chirp Status Indication 1 Beep = Chirp Status Indication “On” 

*

2 Beeps = Chirp Status Indication “Off”
3 Beep = Chirps “ON” with Dual Unlock Pulses On
4 Beep = Chirps “OFF” with Dual Unlock Pulses On

UNLOCK

Last Door Closed 

1 Beep = Automatic Arming “On”, Alarm will arm 10 seconds after  

Automatic Arming

door is closed and rearm 10 seconds after remote disarm. 

2 Beeps = Automatic Arming “On”, Alarm will arm 20 seconds after  

door is closed and rearm 20 seconds after remote disarm.

3 Beeps = Automatic Arming “On”, Alarm will arm 30 seconds after  

door is closed and rearm 60 seconds after remote disarm.

4 Beeps = Automatic Arming “Off” 

*

3

LOCK + UNLOCK

Ignition Key Controlled 1 Beep = Door will Lock 3 seconds after Ignition is Turned “On”. 

Door Locks

Door will not Unlock when Ignition is Turned “Off”.

2 Beeps = Door will Lock 3 seconds after Ignition is Turned “On” 

Door will Unlock when Ignition is Turned “Off”.

3 Beeps = Door will not Lock 3 seconds after Ignition is Turned “On”. 

Door will not Unlock when Ignition is Turned “Off” 

*

.

*

Indicates Default Settings

S t e p   6

Turn Off the Ignition

The horn/siren will emit 1 short chirp and 1 long chirp. You are now

out of the “Remote Feature Programming” mode. The LED is off.

OFF

14

S t e p   5

Passive

Unlocking

Содержание PLUS-4500

Страница 1: ...pyright 2000 Magnadyne Corporation INSTALLATION MANUAL R Vehicle Security For Technical Assistance 800 638 3600 For Fax on Demand Technical Assistance 800 994 9977 Must be a Registered Dealer to Use F...

Страница 2: ...ct the black wire coming from the siren to the frame of the vehicle In many cases you can ground the black wire to one of the screws used to secure the siren Run the remaining brown wire through the f...

Страница 3: ...ires from the switch to the alarm control housing location Installing the Alarm Status LED The LED indicator provided utilizes a push in type mounting Drill a 5 16 hole in the desired location feed th...

Страница 4: ...ulsed Parking Light Relay Output Connect the red white wire to the parking light wire coming from the headlight switch Do not connect the red white wire to the dashboard lighting dimmer switch Damage...

Страница 5: ...ing 5 Step 3 5 Pin Power Harness Installation Continued Red Wire Main Power Input Connect the red wire directly to the battery post for best operation of the alarm system For best current sensing capa...

Страница 6: ...Lock Switch 87 87A 85 86 30 87 87A 85 86 30 To 12 Volts Battery Door Lock Compressor Cut Green Wire Black Wire Unlock Lock Unlock B Unlock Lock Red Wire Lock Orange Wire No Connection 3 Pin Black Plu...

Страница 7: ...k If a signal is received without a resistor the doors will lock Some use 2 resistors One for lock and one for unlock We have developed patented plug in fuse resistors for this application Simply remo...

Страница 8: ...ay pack E Plug in the orange 2 pin plug into the orange socket located at the rear of alarm module To test the dual circuit disable system refer to the starter disable testing procedures located in th...

Страница 9: ...de Switch with 2 Pin Blue Plug Dual Zone Electronic Sensor Plug Applies to PLUS 4000 Only Red Wire 12 Volt Sensor Power Supply Green Wire Sensor Pre Warning Output Black Wire Sensor Ground Supply Blue...

Страница 10: ...sert Red Wire into the First Socket Insert Black Wire into the Eighth Socket Black Wire 2 Button Power Trunk Activation Using Optional ALA RPT Relay Pack Dome Light Supervision Using Optional 30 Amp R...

Страница 11: ...Position S t e p 1 S t e p 2 ON S t e p 3 Turn On Ignition Switch the Valet Switch On then Off 1 Time The siren will stop sounding the parking lights will stop flashing S t e p 4 Switch the Valet Swi...

Страница 12: ...iren will emit 1 short chirp The code has now been learned The transmitters supplied are pre programmed to the receiver module You should use the following instructions when adding a new or replacemen...

Страница 13: ...f 3 Ignition Key Controlled Door Lock Unlock Off OFF ON OFF ON Make Sure the Valet Override Switch is in the Off Position S t e p 1 Switch in Off Position Switch in On Position Valet Override Switch S...

Страница 14: ...after door is closed and rearm 20 seconds after remote disarm 3 Beeps Automatic Arming On Alarm will arm 30 seconds after door is closed and rearm 60 seconds after remote disarm 4 Beeps Automatic Armi...

Страница 15: ...0 20 or 30 seconds have passed depending on remote feature programming you will hear a single chirp The alarm is now armed 6 The LED will flash at a regular rate indicating an armed condition Note Whe...

Страница 16: ...switch is in the off position 2 Turn the ignition key to the on position 3 Within 5 seconds of turning the ignition key place the valet switch to the on position 4 The LED will be on solid indicating...

Страница 17: ...passed Four chirps Tamper indicator alarm is disarmed Power Door Lock Unlock If Installed 1 Press the lock button on the transmitter the locks will become locked 2 Press the unlock button on the tran...

Страница 18: ...emote Feature Programming ignition controlled locking is active 3 seconds after the ignition key is set the on position the door locks will automatically become locked When the ignition key is turned...

Страница 19: ...Connection Dip Switches Black Wire Antenna Do Not Ground Power Door Lock Harness Socket Black Valet Override Socket Blue Black Wire Ground to Vehicle Frame Yellow Wire To Ignition Switched 12V Red Wir...

Страница 20: ...PLUS45IM 11 19 99 Rev F...

Отзывы: