NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR ANY REASON.
BEFORE TOUCHING any parts of the oven, always remove the power plug from the outlet.
For about 60 seconds after the oven stops, an electric charge remains in the high voltage capacitor. When replacing or checking, you must wait to permit the capacitor
discarding.
Troubleshooting guide
4.8
Bad Cooking Performance
Anomaly
Possible Cause
Corrective Action
section
Bad performance
Heating elements not working
Check the connection of the heating elements
--
If there in not power on the heating elements check
relays.
If the electronic control relay not switching replace the
units.
7.18
If there is not power on the heating elements check
safety thermostat.
If the thermostat not switching replace the units
7.11
Check the power on the heating elements and replace the
elements if needed.
7.5
7.6
Check the protection fuse near Power Board and replace
it if needed.
7.12
Convection fan not working
properly
See the convection fan problem
4.4
There is not sealing between
door and gasket
The hinges system or the door gasket are damaged.
Replace the units
7.15
7.10
Uneven cooking
Inconsistent intensity of
microwave by their
characteristics.
--