Care and Maintenance Instructions Model : Z3314--44
Further information Phone (03) 9761 4603 [email protected]
MAINTENANCE FOR FIVE HOLE/THREE LEVER TAPWARE
INSTRUCTIONS FOR REPLACEMENT OF THE HOT OR COLD CARTRIDGE
Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or
kinking of supply hoses.
If the hand spray is leaking, do not replace the diverter. Service or replace the hand
spray if there is a continous leak.
❶
Turn off the hot and cold supply lines to the tap set.
(Not shown).
Remove the handle and retaining flange. Refer to
“Removing and replacing a handle” section,
page13.
❷
Remove the cartridge with a smooth jawed 17mm
shifter.
❸
Install new cartridge.
Secure the cartridge with a smooth jawed shifter.
❹
Install lever and retaining flange
. DO NOT USE A
SHIFTER TIGHTEN BY HAND ONLY!
Turn on supply lines and test for leaks. (Not shown).
Continue…….
14
Note:
Do not over tighten as this could damage the ceramic
cartridge!