manualshive.com logo in svg
background image

HyTronic

®

 with SSPS User Guide

 

Installation Instructions 

For single supply and dual supply HyTronic faucets

1

For additional technical assistance, call 800/TEC-TRUE (800-832-8783) or visit our website at chicagofaucets.com.

Traditional Lavatory

Edge

Curve

Contemporary Lavatory

Wallmount

SSPS Generator

Safety Information

Read this entire user guide to ensure proper installation. Compliance and conformity to local codes and ordinances is the responsibility of the installer.  

The following safety notes must always be complied with during handling of this product:

•  Make sure there is enough space and lighting available during installation and service.

•  Do not modify or convert this Chicago Faucets product yourself. All warranties will be voided.

Important

•  Installation may be performed at different times of construction by different individuals. For this reason, these instructions should be left on-site with the  

facility or maintenance manager.

•  Pressurized plumbing fixtures shall be installed in accordance with manufacturer’s recommendations. The supply piping to these devices shall be securely 

anchored to the building structure to prevent installed device from unnecessary movement when operated by the user. Care shall be exercised when installing 

the device to prevent marring the exposed significant surface.

•  Do not use pipe dope.

•  Flush all the water supply lines before making connections.

Mounting of Deck Mount Faucet 

(Single Supply Unit Shown)

1.   Mount cover plate if 

required. Plumber’s 

putty is recommended 

to seal cover plate to 

the sink. Security pin 

must be located on 

the left side.

4.  Place nut onto 

mounting rod and 

tighten with wrench. 

If faucet was installed 

with cover plate, secure 

with basin washer, flat 

washer and locknut.

2.    Mount gasket and put 

faucet into sink.

5.     Install aerator and 

tighten with aerator key 

(supplied). Aerator: 1.0 

gpm (standard) and 

optional 0.5 gpm insert. 

(Use 1.5 gpm for dual 

supply).

3.    Mount bracket from 

underneath. Place 

hoses through large 

opening and mounting 

rod through small 

opening. Make sure 

flange sits securely 

against surface.

Prerequisites

• Supply valve is installed

• Water supply lines are flushed properly

Important

•  It is not necessary to unscrew the connection between braided hose and housing to install the product.

•  Do not remove protective covering from sensor until starting up faucet operation.

• Do not tighten locknut before step 4 is completed.

NoTe:   If faucet was installed with cover plate, secure with basin washer, flat washer and locknut.

Mounting of Wall Mount Faucet 

(Single Supply Unit Shown)

Prerequisites

• Supply valve is installed

• Water supply lines are flushed properly

Important

•  It is not necessary to unscrew the connection between braided hose and housing to  

install the product.

•  Do not remove protective covering from sensor until starting up faucet operation.

1.  Mount gasket, put faucet into  

opening and tighten. Install aerator 

and tighten with aerator key  

(supplied).

2. 

 

For gooseneck faucets, tighten 

spout with wrench. Aerator: 1.0 gpm 

(standard) and optional 0.5 gpm insert

Overview

Chicago Faucets deck mounted faucets feature cast brass bodies and precision cartridges for years of reliable operation. Metering models with adjustable  

cycle time offer true water savings.

Notice to the Installer

• Read this entire instruction sheet before installing to ensure proper installation.

• Installation must comply with local codes and ordinances.
Pressurized plumbing fixtures shall be installed in accordance with manufacturer’s recommendations. The supply piping to these devices shall be securely 

anchored to the building structure to prevent installed device from unnecessary movement when operated by the user. Care shall be exercised when installing 

the device to prevent marring the exposed surface.
NOTE: The information in this manual is subject to change without notice.
Please leave this manual with the facility manager after completing the faucet installation. This document contains information necessary for routine maintenance 

and servicing.
NOTE: Before installation, turn off water supplies to existing faucet and remove faucet if replacing. Clean faucet basin and clear away debris. Flush all supply 

lines before connecting to faucet. Failure to do so can result in debris clogging the inlets and/or cartridges.

NoTe: Before installing a new ceramic cartridge flush lines completely.

Mounting of SSPS Generator

The SSPS Generator comes with all the components needed for  

installation, however, some tools and supplies are not included.

• Basin Wrench 

• Hand Drill

• Adjustable Wrench 

• Adjustable Locking Pliers

Includes

• SSPS Generator Unit

• Electronics Module and Holder

• Green Power Adapter

• Hose

1.    Connect SSPS unit.  

Attach to faucet and  

install water supply line.

4.    Drill holes. Drill holes 

for screw anchors.

2.    Position SSPS under 

sink. Carefully position 

to allow connection of 

water lines and wiring.

5.    Secure SSPS to wall. 

Insert anchors into holes 

and mount SSPS unit to 

wall with supplied screws.

3.    Mark holes. Position 

mounting bracket and 

mark mounting holes.

6.    Attach inlet hose to supply 

and turn on water. With 

water on, check system  

for leaks.* 

*For dual-supply SSPS 

models, connect the hot 

water supply line to the 

SSPS unit and the cold 

water supply line directly  

to the faucet.

9.    Remove cover and 

connect faucet wire to

  SSPS and secure into

  wire harness.

7.    Fully  open  supply 

valve.

8.  Remove all items from  

  sink.

11.  Remove protective  

covering from sensor.

    Wait for 15 seconds 

for faucet to calibrate 

to its environment.

10.    Attach the cover. Faucet is ready to run through 

programming sequence.

IMPORTANT: 

Do not use pipe dope on faucet and supply connections. 

Possible solenoid contamination could occur and will void any warranty.

Gooseneck