This example assumes that a CP40 control panel has been wired to the 
Canlan and configured appropriately. In the first edit box (Panel Address) 
the control panel panel address must be entered as set on the CP40 address 
dip switches. In the next entry, enter the number of the new virtual trunk we 
defined in the Network Trunk Definitions dialog. Enter one or more card 
readers each with its own unique reader id and name and then press OK. 
 
We now have defined both the Canlan and one CP40 control panel which is 
connected to it. Once again, check the communication statistics by choosing 

VIEW -> COMMUNICATIONS

 from the menu. 

 

 

 

Содержание Canlan

Страница 1: ...Canlan INSTALLATION MANUAL August 2014...

Страница 2: ......

Страница 3: ...Network Connection 9 Making a Connection 11 Setup and Configuration 14 Address Configuration 14 Operational Mode 15 Remote Diagnostics 16 Serial Interface 17 Saving the Settings 17 Commands 18 Connec...

Страница 4: ...16 CP40 or 30 Smartlock control panels On Maestro systems network traffic only occurs when events or commands need to be relayed between the host and the control panels Bandwidth is conserved through...

Страница 5: ...face and the status LEDs A RS232 Port Activity LED flashes when there is activity on the RS232 interface B RS485 Port Activity LED flashes when there is activity on the RS485 interface C Link Activity...

Страница 6: ...connector on the back of the Canlan NOTE a power outage will result in a 20 30 loss of connectivity to the device 12 VDC Battery Backup recommended The Canlan can be wired via the RS485 header connect...

Страница 7: ...s a 3 wire interface with the following pin outs 1 Not Used 2 RX 3 TX 4 Not Used 5 Gnd 6 Not Used 7 Not Used 8 Not Used RS485 Header Connector The RS485 header connector has the following pin outs 1 R...

Страница 8: ...anual August 2014 Rev 1 2 Installing the Canlan Software 1 Insert the mini CD into your computer s CD drive 2 Go to My Computer and double click your computer s CD drive 3 Double click Setup exe 4 Fol...

Страница 9: ...onnection SERIAL CONNECTION 1 Connect the CanLan to the PC using the DB9 data cable provided 2 Continue to the Making a Connection section on page11 NETWORK CONNECTION Before connecting the CanLan and...

Страница 10: ...rotocol TCP IP from the list and press the Properties button 4 Write down your current settings 5 Select Use the following IP address and enter IP address 10 0 0 1 Subnet Mask 255 255 255 0 Default Ga...

Страница 11: ...n software to the CanLan during the 20 second configuration period If the 20 second configuration period expires before you make a connection simply power the CanLan off and then power it back on agai...

Страница 12: ...rial Port and choose the appropriate COM Port from the drop down menu 7 If you are using a network connection choose Connect via Network and enter the CanLan s default IP address 10 0 0 100 The COM Po...

Страница 13: ...Troubleshooting Tips If a connection cannot be established the connection icon will remain red and the status line will report Unit Offline Verify the CanLan Connection If you are using a network con...

Страница 14: ...iagnostics and Serial Interface Each section reflects a group of settings that will be stored in the Canlan s flash memory ADDRESS CONFIGURATION The Address Configuration section defines the static IP...

Страница 15: ...he idle auto disconnect inactivity timer drops any active host connection after a specified interval in minutes during which no data is transmitted or received This option helps prevent against a hung...

Страница 16: ...ore details The Canlan implements a set of diagnostic commands which can be issued from the Advanced Diagnostic software tool In addition it continues to support execution tracing at selectable detail...

Страница 17: ...not the cable type used to configure the Canlan RS485 Interface If the Canlan will be connected to the control panels using an RS485 connector choose RS485 Interface Setup When an operational mode is...

Страница 18: ...he Canlan replacing the existing settings Save downloads the current settings to the Canlan and writes them to flash memory Version displays the Canlan firmware revision information Default sets all p...

Страница 19: ...nlan to a Control Panel The Canlan may be connected to up to 16 CP40 access control panels or up to 30 SmartLock access control panels Refer to the SmartLock Pro Installation Manual or the CP40 Instal...

Страница 20: ...lation and Configuration guide for details NOTES ADDRESS 1 SHOWN Dipswitch 1 is OFF CANLAN TCP IP CONTROLLER SMARTLOCK CONTROLLER 1 ON OFF ON 8 1 5V 12V ADDRESS SWITCH B A GND B A GND SHIELD GND 12 VD...

Страница 21: ...485 5 8 7 GND 12 VDC NOTE It is highly recommended that the Canlan be powered by 12 VDC output from a Cansec access control panel with battery backup This will prevent connectivity loss during a power...

Страница 22: ...a connection to the Canlan from the appropriate host software The following sections give a brief overview of how to define a new Canlan using either Maestro software Smartlock Pro software MAESTRO C...

Страница 23: ...estart the software and view the current connection status of the trunk by choosing VIEW COMMUNICATIONS from the menu The communications status window will be displayed Select the trunk line from the...

Страница 24: ...t be entered as set on the CP40 address dip switches In the next entry enter the number of the new virtual trunk we defined in the Network Trunk Definitions dialog Enter one or more card readers each...

Страница 25: ...on Problems If there is a communication problem between the Canlan and the access control panel it will be reflected in the Timeouts column for each respective control panel The Timeouts column counts...

Страница 26: ...inition dialog at right is displayed Enter the address of the new control panel that was connected to the Canlan and give it a name Select the Connection tab Direct Serial Connection choose this optio...

Страница 27: ...EW STATISTICS from the menu bar The communication statistics window will appear displaying statistics about connected control panels as well as information regarding the current Canlan connection stat...

Страница 28: ...within a second or two after the connection is initiated If the status remains in the Connecting state then there maybe an issue with that Canlan configuration or socket connectivity issues through r...

Страница 29: ...rs code and are fixed The remaining 3 bytes are unique for each device produced by that manufacturer The manufacture s code for the Canlan is 00 90 C2 with the remain 3 bytes differing for each unit I...

Страница 30: ...allation Manual August 2014 Rev 1 2 If the unit has not been installed yet the last three bytes 6 characters are stenciled on the CPU module as shown below The MAC address is the same as the previous...

Страница 31: ...tware including IP address is correct and then press SAVE Power off the Canlan wait a few seconds and power it back on again LED B should stop flashing while in the 20 second configuration mode Rechec...

Отзывы: