12. Adjusting Height of the Corona Wires
Figure 10-218
Note:
The height (position) of the corona wire of the primary and transfer corona assemblies can be
adjusted by turning the screw at the back of the corona wire.
Turning the screw once causes the height of the corona wire to change by about 0.7 mm.
Corona assembly
Primary corona
assembly
Transfer corona
assembly
Allowable range
±2 mm
±2 mm
Standard position
Approx. 10.5 mm
Approx. 10 mm