CHAPTER 4 IMAGE FORMATION SYSTEM
COPYRIGHT © 1999 CANON INC. CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-5
III. PRIMARY/TRANSFER CORONA CURRENT AND
GRID BIAS VOLTAGE CONTROL SYSTEM
A.
Outline
The circuit shown in Figure 4-102 controls the primary/transfer coronal current and the bias
voltage of the grid of the primary corona. Main functions are as follows:
1.
Switching primary/transfer corona current ON/OFF
2.
Maintaining primary/transfer corona current constant
3.
Switching primary corona grid bias voltage
4.
Switching primary corona grid bias ON/OFF
In order to eliminate the effect of changes in atmospheric conditions on the effectiveness of the
corona discharge, the current to the primary corona wire is maintained constant.
The primary corona and transfer corona currents are switched ON and OFF by the HVT ON
command (HVTON).
The grid bias voltage is switched by the GRID ON signal (GRDON).
B.
Switching Primary/Transfer Corona Current ON/OFF
a.
When HVTON=1,
Differential amplifier goes OFF.
Variable pulse width oscillator goes OFF.
High-voltage transformer goes OFF.
b.
When HVTON=0,
Differential amplifier goes ON.
Variable pulse width oscillator goes ON.
High-voltage transformer goes ON.
Содержание NP6317
Страница 4: ......
Страница 10: ......
Страница 22: ......
Страница 24: ......
Страница 36: ......
Страница 58: ......
Страница 90: ......
Страница 112: ......
Страница 128: ......
Страница 130: ......
Страница 142: ......
Страница 144: ......
Страница 158: ......
Страница 187: ......
Страница 236: ......
Страница 238: ......
Страница 242: ......
Страница 244: ......
Страница 246: ......
Страница 248: ...0499AB0 91 1 PRINTED IN JAPAN IMPRIME AU JAPON This pubication is printed on 70 reprocessed paper ...