V. MALFUNCTION TROUBLESHOOTING
Perform troubleshooting according to the malfunction diagnosis flowchart (Figure 4-1-1). If an
“malfunction” is found, the defective part must be located and rectified by the following proce-
dures.
V-1.
No AC power
<Possible causes>
1) Blown fuse (FU101)
Action:
Replace the fuse (FU101).
2) The engine controller PCB is defective.
Action:
Replace the engine controller PCB.
V-2.
No DC power
<Possible causes>
1) No AC power is supplied.
Action:
Make a check according to V -1 “No AC power”.
2) The overcurrent/overvoltage detection circuit is activated.
Action:
Unplug the power cord, wait for two minutes or more, and then plug the cord back.
If the problem still remains, find the cause of activation of the overcurrent/over-
voltage detection circuit in the power supply unit.
3) Blown fuse (FU102)
Action:
Replace the fuse (FU102).
4) The engine controller PCB is defective.
Action:
Replace the engine controller PCB.
CHAPTER 4
4 - 16
Содержание LASER SHOT LBP-1210
Страница 8: ......
Страница 84: ...1 76 CHAPTER 1 ...
Страница 86: ......
Страница 129: ...This page intentionally left blank CHAPTER 2 2 43 ...
Страница 134: ...CHAPTER 2 2 48 ...
Страница 136: ......
Страница 142: ...4 Unhook the two left claws and remove the front guide unit Left claws Front guide unit Figure 3 2 14 CHAPTER 3 3 6 ...
Страница 164: ......
Страница 191: ...APPENDIX I GENERAL TIMING CHART A 1 II GENERAL CIRCUIT DIAGRAM A 2 III LIST OF SIGNALS A 3 IV MESSAGES TABLE A 5 ...
Страница 192: ......
Страница 202: ...The printing paper contains 70 waste paper PRINTED IN JAPAN IMPRIME AU JAPON CANON INC ...