8
8
8-127
8-127
Service Mode > FAX > List of NUM
Service Mode > FAX > List of NUM
List of MENU
Menu switch registration mode
No.
Parameter
Selection
01 - 05 Not in use
06
Telephone line monitor
0 - 3
0: DIAL
1: SERVICEMAN1
2: SERVICEMAN2
3: OFF
07
Transmission level (ATT)
0 - 15
08
Upper limit of V.34 modulation speed
0 - 5
0: 3429 BAUD
1: 3200 BAUD
2: 3000 BAUD
3: 2800 BAUD
4: 2743 BAUD
5: 2400 BAUD
09
Upper limit of V.34 data speed
0-13
0: 33.6 kbps
1: 31.2 kbps
2: 28.8 kbps
3: 26.4 kbps
4: 24.0 kbps
5: 21.6 kbps
6: 19.2 kbps
7: 16.8 kbps
8: 14.4 kbps
9: 12.0 kbps
10: 9.6 kbps
11: 7.2 kbps
12: 4.8 kbps
13: 2.4 kbps
10
OFF Hook signal frequency
0-2
0: 50 Hz
1: 25 Hz
2: 17 Hz
11 - 20 Not in use
T-8-65
List of NUM
Numeric parameter setting mode
No.
Parameter
Allowable setting range
01
Not in use
02
RTN transmission criteria X
1 to 99 %
03
RTN transmission criteria n
2 to 99 times
04
RTN transmission criteria m
1 to 99 lines
05
NCC pause (before ID code)
1 to 60 sec
06
NCC pause (after ID code)
1 to 60 sec
07
Not in use
08
STORED_DIAL_MODE wait timer
0 to 65 sec
09
Not in use
10
T.30 T0 timer
55 sec principally
11
T.30 T1 timer (for incoming transmission)
0 to 9999
(France: 3500, Others: 3000)
12
Maximum incoming lines
0 to 65535 (line)
0: without limitation
13
T.30 EOL timer
500 to 3000
(set to 55 sec by default)
14
Not in use
15
Threshold between hokking nad on-hook
0 to 999
16
Lead time to the first response when switching between FAX
and TEL
0 to 9
17
Duration to activate pseudo-RBT cadence
0 to 999
18
Duration to deactivate pseudo-RBT cadence (short)
0 to 999
19
Duration to deactivate pseudo-RBT cadence (long)
0 to 999
20
Duration to activate pseudo-ring cadence
0 to 999
21
Duration to deactivate OFF Hook cadence (short)
0 to 999
22
Duration to deactivate OFF Hook cadence (long)
0 to 7
23 Not in use
24
Not in use
25
CNG monitor duration while the answering device is
activated
0 to 999
26 Not in use
27
Not in use
28
Not in use
29
Off-hook PCB duty settings
(For NAC, setting can be made with SPL71100 in special
management mode.)
20 (*10ms)
30 - 48 Not in use
49
NSX MODEL ID
0 to 4095
50
Not in use
51
Threshold to detect hook
10 to 9999
52
Not in use
53
Set DTMF calling counts when receiving FAX remotely
10 to 9999 (default 25)
Содержание imageRUNNER C1335 Series
Страница 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 429: ...7 7 7 58 7 58 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101 PS103 PS102 PS101 F 7 3 F 7 4 ...
Страница 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Страница 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...
Страница 602: ...10 3 10 3 Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...