8
8
8-46
8-46
Service Mode > COPIER > ADJUST > V-CONT
Service Mode > COPIER > ADJUST > V-CONT
COPIER> ADJUST> V-CONT
VCONT-C
Adj of C-color contrast potential
Details
To adjust the contrast potential for C.
As the value is incremented by 1, the contrast potential changes by 10V.
+: Image becomes darker.
-: Image becomes lighter.
When the value is too large, paper winds around the Fixing Roller or a
transfer failure occurs.
In a low humidity environment (e.g. winter in North America or Japan),
the output may not be changed by increasing the value.
In principle, the adjustment of the density should be performed in
Adjustment/Maintenance> Adjust Image Quality> Density Adjustment
Mode.
Use case
When adjusting the density of D-max control in the case that an image
density failure occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
2) Execute Auto Adjust Gradation> Full Adjust.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-5 to 5
Unit
10 V
Default value
0
Related service mode COPIER> ADJUST> V-CONT> VCONT-Y/M/K
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust
Adjustment/Maintenance> Adjust Image Quality> Density Adjustment
Mode
COPIER> ADJUST> V-CONT
VCONT-K
Adj of Bk-color contrast potential
Details
To adjust the contrast potential for Bk.
As the value is incremented by 1, the contrast potential changes by 10V.
+: Image becomes darker.
-: Image becomes lighter.
When the value is too large, paper winds around the Fixing Roller or a
transfer failure occurs.
In a low humidity environment (e.g. winter in North America or Japan),
the output may not be changed by increasing the value.
In principle, the adjustment of the density should be performed in
Adjustment/Maintenance> Adjust Image Quality> Density Adjustment
Mode.
Use case
When adjusting the density of D-max control in the case that an image
density failure occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
2) Execute Auto Adjust Gradation> Full Adjust.
Caution
Do not use this when the machine is operating correctly.
Display/adj/set range
-5 to 5
Unit
10 V
Default value
0
Related service mode COPIER> ADJUST> V-CONT> VCONT-Y/M/C
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust
Adjustment/Maintenance> Adjust Image Quality> Density Adjustment
Mode
Содержание imageRUNNER C1335 Series
Страница 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 429: ...7 7 7 58 7 58 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101 PS103 PS102 PS101 F 7 3 F 7 4 ...
Страница 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Страница 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...
Страница 602: ...10 3 10 3 Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...