8
8
8-43
8-43
Service Mode > COPIER > ADJUST > DENS
Service Mode > COPIER > ADJUST > DENS
COPIER> ADJUST> DENS
DMAX-M
Adj D-max ctrl M-color dens target VL
Details
An image failure might occur because the density target value of the
D-max control becomes out of the setting table due to environment
change.
Adjust the offset of the magenta density target value of D-max control.
Use case
When any image failure occurs due to environment change
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
Caution
Do not use this at the normal service.
Display/adj/set range
-8 to 8
Default value
0
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust, Quick Adjust
DMAX-C
Adj D-max ctrl C-color dens target VL
Details
An image failure might occur because the density target value of the
D-max control becomes out of the setting table due to environment
change.
Adjust the offset of the cyan density target value of D-max control.
Use case
When any image failure occurs due to environment change
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
Caution
Do not use this at the normal service.
Display/adj/set range
-8 to 8
Default value
0
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust, Quick Adjust
P-TG-Y
Adj of ATR control Y-color target value
Details
To adjust the offset of the ATR patch target value for Y.
When the target value determined upon initialization is changed, density
and the TD ratio are also changed.
Density is increased when the value is increased, and fogging/scattering
is alleviated when the value is decreased.
Use case
When density failures, fogging, etc. occur
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
2) Make 10 prints of approx. 10% image ratio (ex. COPIER> TEST> PG>
TYPE: 16) 20 times.
3) Execute Auto Adjust Gradation> Full Adjust.
Caution
Execute the Auto Adjust Gradation first to increase the density. If you
adjust the offset of the target value, fogging might get worse.
Display/adj/set range
-4 to 4
Default value
0
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust
COPIER> ADJUST> DENS
P-TG-M
Adj of ATR control M-color target value
Details
To adjust the offset of the ATR patch target value for M.
When the target value determined upon initialization is changed, density
and the TD ratio are also changed.
Density is increased when the value is increased, and fogging/scattering
is alleviated when the value is decreased.
Use case
When density failures, fogging, etc. occur
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
2) Make 10 prints of approx. 10% image ratio (ex. COPIER> TEST> PG>
TYPE: 16) 20 times.
3) Execute Auto Adjust Gradation> Full Adjust.
Caution
Execute the Auto Adjust Gradation first to increase the density. If you
adjust the offset of the target value, fogging might get worse.
Display/adj/set range
-4 to 4
Default value
0
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust
P-TG-C
Adj of ATR control C-color target value
Details
To adjust the offset of the ATR patch target value for C.
When the target value determined upon initialization is changed, density
and the TD ratio are also changed.
Density is increased when the value is increased, and fogging/scattering
is alleviated when the value is decreased.
Use case
When density failures, fogging, etc. occur
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
2) Make 10 prints of approx. 10% image ratio (ex. COPIER> TEST> PG>
TYPE: 16) 20 times.
3) Execute Auto Adjust Gradation> Full Adjust.
Caution
Execute the Auto Adjust Gradation first to increase the density. If you
adjust the offset of the target value, fogging might get worse.
Display/adj/set range
-4 to 4
Default value
0
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust Gradation>
Full Adjust
Содержание imageRUNNER C1335 Series
Страница 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 429: ...7 7 7 58 7 58 Error Jam Alarm Jam Code Jam Type Error Jam Alarm Jam Code Jam Type PS101 PS103 PS102 PS101 F 7 3 F 7 4 ...
Страница 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Страница 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...
Страница 602: ...10 3 10 3 Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...