2
2
2-68
2-68
ATVC control
This control prevents transfer failure due to environmental change or deterioration of the
primary transfer roller or the secondary transfer roller
Primary transfer ATVC
Execution timing
1) When the power is turned ON
2) When replacing with a new drum unit
3) At recovery from sleep mode
4) At post-rotation after the total reaches 500 prints
5) When the environment is changed
Catuion:
The total print is counted separately between the color mode and the Bk mode. This
control is executed when the counter of either mode reaches the specified number.
Control description
1) Monitoring current value of the primary transfer DC bias is detected
2) Optimal primary charging current value is determined based on the temperature/
humidity data of Environment sensor 1.
3) The primary transfer DC bias is determined to apply to the primary transfer roller
●
•
Secondary transfer ATVC
Execution timing
1) When the power is turned ON
2) At every print job
Control description
1) Monitoring current value of the secondary transfer DC bias is detected
2) Optimal primary charging current value is determined based on the temperature/
humidity data of environment sensor 2.
3) The secondary transfer DC bias is determined to apply to the secondary transfer roller
Environment
sensor2
(UN50)
Environment
sensor1
(UN22)
Primary transfer
roller
Secondary transfer
outer roller
DC controller(UN1)
Primary transfer DC Bias
Secondary transfer
DC Bias
Current monitoring
signal
Current monitoring
signal
•
F-2-110
F-2-110
Содержание IMAGERUNNER ADVANCE C5045
Страница 8: ...1 1 Product Overview Product Lineup Feature Specifications Name of Parts ...
Страница 47: ...2 2 2 23 2 23 Air flow of fixing system F 2 40 F 2 40 Air flow around the operation system F 2 41 F 2 41 ...
Страница 191: ...3 3 Periodical Service Consumable Parts and Cleaning Parts Cleaning Parts ...
Страница 193: ...3 3 3 3 3 3 Recycle toner bottle Dust blocking glass cleaning pad Toner filter F 3 1 F 3 1 ...
Страница 195: ...3 3 3 5 3 5 Roller pressure Fixing bearing Fixing bearing Film unit 100V 120V 230V F 3 3 F 3 3 ...
Страница 216: ...4 4 4 19 4 19 Fan Fixing heat exhaust fan 1 FM1 Fixing heat exhaust fan 2 FM2 Delivery fan 2 FM9 F 4 12 F 4 12 ...
Страница 229: ...4 4 4 32 4 32 Speaker SP1 Leakage breaker ELCB1 F 4 19 F 4 19 ...
Страница 232: ...4 4 4 35 4 35 Main power supply switch SW1 Environment switch SW2 F 4 21 F 4 21 ...
Страница 240: ...4 4 4 43 4 43 Conector 25 25 25 25 28 27 30 29 13 24 23 1 10 22 7 31 6 5 4 3 2 17 26 12 16 19 18 21 11 20 14 9 8 F 4 25 ...
Страница 242: ...4 4 4 45 4 45 24 32 30 35 34 33 31 1 2 11 8 7 12 6 5 4 9 25 18 17 10 3 15 16 13 14 19 21 20 F 4 26 ...
Страница 244: ...4 4 4 47 4 47 26 24 19 20 6 9 17 1 4 5 3 2 16 12 10 15 14 13 18 8 28 29 7 21 27 31 22 23 11 25 F 4 27 ...
Страница 246: ...4 4 4 49 4 49 14 13 12 11 20 21 22 23 25 6 4 1 3 2 5 27 7 8 9 18 19 10 33 31 26 17 15 30 34 24 29 16 32 F 4 28 ...
Страница 248: ...4 4 4 51 4 51 19 3 1 2 7 5 4 10 11 8 12 9 6 15 13 16 17 14 25 24 23 22 21 20 F 4 29 ...
Страница 252: ...4 4 4 55 4 55 31 23 24 2 11 16 1 3 34 4 9 30 22 19 21 18 20 15 32 14 8 10 7 12 5 6 F 4 31 ...
Страница 254: ...4 4 4 57 4 57 26 25 21 22 32 15 19 29 18 30 31 20 3 4 8 12 13 14 10 1 2 5 6 9 7 32 11 27 F 4 32 ...
Страница 256: ...4 4 4 59 4 59 13 8 2 3 1 7 6 4 5 11 14 12 10 9 F 4 33 ...
Страница 258: ...4 4 4 61 4 61 11 15 18 19 22 12 13 14 16 17 20 21 6 5 7 9 8 10 1 2 3 4 F 4 34 ...
Страница 260: ...4 4 4 63 4 63 18 14 10 6 17 20 16 12 8 19 15 11 7 4 3 2 1 13 9 5 F 4 35 ...
Страница 264: ...4 4 4 67 4 67 8 1 2 4 5 6 3 7 14 12 10 13 9 F 4 37 ...
Страница 368: ...5 5 Adjustment Main Controller ...
Страница 371: ...6 6 Troubleshooting Initial Check Test Print Troubleshooting items Upgrading procedure ...
Страница 389: ...7 7 Error Code Overview Error Code Jam Code Alarm Code ...
Страница 466: ...8 8 Service Mode Overview BOARD COPIER FEEDER SORTER ...
Страница 902: ...9 9 9 2 9 2 ...
Страница 1084: ...Service Tools General Circuit Diagram General Timing Chart User Mode Backup Data Appendix ...