2
2
2-161
2-161
Q13: In order to confirm Service mode menu transmission, are some set up by the device
side? Moreover, what is Service mode menu set as the object of transmission?
A13: No steps peculiar to Transmitting Servicemode menu.
Following servicemode data will be sent to UGW at each event mentioned below.
F-2-255
F-2-255
Troubleshooting
No.1
A communication test (COM-TEST) results NG!
Causes: Initial settings or network conditions is incomplete.
Remedy: Check and take actions mentioned below.
1) Check network connections
Is the status indicator LED for the HUB port to which the main unit is connected ON?
YES: Proceed to Step 2).
NO: Check that the network cable is properly connected.
2) Confirm loop back address
a) Settings/ Registration/ Registration > System administration settings > Network settings
> TCP/ IP settings > IPv4 settings > PING command. Input 127.0.0.1, and touch the Start
button.
Is the response from the host displayed?
YES: Proceed to Step 3).
NO: There is a possibility that the main unit's network settings are wrong. Check the details
of the IPv4 settings once more.
3) Confirmation from another PC connected to same network.
a) Request the user to ping the main unit from a PC connected to same network.
F-2-256
F-2-256
Содержание IMAGERUNNER ADVANCE C5045
Страница 8: ...1 1 Product Overview Product Lineup Feature Specifications Name of Parts ...
Страница 47: ...2 2 2 23 2 23 Air flow of fixing system F 2 40 F 2 40 Air flow around the operation system F 2 41 F 2 41 ...
Страница 191: ...3 3 Periodical Service Consumable Parts and Cleaning Parts Cleaning Parts ...
Страница 193: ...3 3 3 3 3 3 Recycle toner bottle Dust blocking glass cleaning pad Toner filter F 3 1 F 3 1 ...
Страница 195: ...3 3 3 5 3 5 Roller pressure Fixing bearing Fixing bearing Film unit 100V 120V 230V F 3 3 F 3 3 ...
Страница 216: ...4 4 4 19 4 19 Fan Fixing heat exhaust fan 1 FM1 Fixing heat exhaust fan 2 FM2 Delivery fan 2 FM9 F 4 12 F 4 12 ...
Страница 229: ...4 4 4 32 4 32 Speaker SP1 Leakage breaker ELCB1 F 4 19 F 4 19 ...
Страница 232: ...4 4 4 35 4 35 Main power supply switch SW1 Environment switch SW2 F 4 21 F 4 21 ...
Страница 240: ...4 4 4 43 4 43 Conector 25 25 25 25 28 27 30 29 13 24 23 1 10 22 7 31 6 5 4 3 2 17 26 12 16 19 18 21 11 20 14 9 8 F 4 25 ...
Страница 242: ...4 4 4 45 4 45 24 32 30 35 34 33 31 1 2 11 8 7 12 6 5 4 9 25 18 17 10 3 15 16 13 14 19 21 20 F 4 26 ...
Страница 244: ...4 4 4 47 4 47 26 24 19 20 6 9 17 1 4 5 3 2 16 12 10 15 14 13 18 8 28 29 7 21 27 31 22 23 11 25 F 4 27 ...
Страница 246: ...4 4 4 49 4 49 14 13 12 11 20 21 22 23 25 6 4 1 3 2 5 27 7 8 9 18 19 10 33 31 26 17 15 30 34 24 29 16 32 F 4 28 ...
Страница 248: ...4 4 4 51 4 51 19 3 1 2 7 5 4 10 11 8 12 9 6 15 13 16 17 14 25 24 23 22 21 20 F 4 29 ...
Страница 252: ...4 4 4 55 4 55 31 23 24 2 11 16 1 3 34 4 9 30 22 19 21 18 20 15 32 14 8 10 7 12 5 6 F 4 31 ...
Страница 254: ...4 4 4 57 4 57 26 25 21 22 32 15 19 29 18 30 31 20 3 4 8 12 13 14 10 1 2 5 6 9 7 32 11 27 F 4 32 ...
Страница 256: ...4 4 4 59 4 59 13 8 2 3 1 7 6 4 5 11 14 12 10 9 F 4 33 ...
Страница 258: ...4 4 4 61 4 61 11 15 18 19 22 12 13 14 16 17 20 21 6 5 7 9 8 10 1 2 3 4 F 4 34 ...
Страница 260: ...4 4 4 63 4 63 18 14 10 6 17 20 16 12 8 19 15 11 7 4 3 2 1 13 9 5 F 4 35 ...
Страница 264: ...4 4 4 67 4 67 8 1 2 4 5 6 3 7 14 12 10 13 9 F 4 37 ...
Страница 368: ...5 5 Adjustment Main Controller ...
Страница 371: ...6 6 Troubleshooting Initial Check Test Print Troubleshooting items Upgrading procedure ...
Страница 389: ...7 7 Error Code Overview Error Code Jam Code Alarm Code ...
Страница 466: ...8 8 Service Mode Overview BOARD COPIER FEEDER SORTER ...
Страница 902: ...9 9 9 2 9 2 ...
Страница 1084: ...Service Tools General Circuit Diagram General Timing Chart User Mode Backup Data Appendix ...