■ Standby temperature control
Max. 10 sec
Fixing
temperature
STBY
INTR
PRNT
Flying start
control
temperature
Time
Command for
flying start
● Flying start temperature control
Purpose:
• To reduce the print time (FPOT) of the 1st sheet
Starting conditions:
• When opening the copyboard cover or ADF, and also the detection temperature of the main thermistor is less than 100 deg
C.
• When the original sheet is set on the ADF tray, and also the detection temperature of the main thermistor is less than 100
deg C.
• When the main power switch is turned ON or the machine condition is shift from the sleep mode to standby, and also the
detection temperature of the main thermistor is less than 155 deg C.
Control description:
• The target control temperature is set to 165 deg C and the fixing motor starts to rotate with a half speed. The control continues
for maximum 10 seconds.
2. Technical Explanation
69
Содержание imageRUNNER 2520 Series
Страница 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 16: ...Product Overview 1 Product Lineup 7 Features 10 Specifications 11 Name of Parts 15 Operation 18 ...
Страница 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Страница 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Страница 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Страница 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Страница 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Страница 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Страница 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Страница 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Страница 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Страница 223: ...Jam Code Main Unit 550 sheet 1st cassette model S1 S5 S7 S19 S12 S42 S40 7 Error Jam Alarm 213 ...
Страница 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Страница 314: ...Example of report display 8 Service Mode 304 ...