Execute this after replacing the CCD unit.
● #SCAN> READER> FUNCTION> CCD> DF-WLVL1
ADF white level adjustment (platen board cover scan/stream reading scan)
1. Place a paper that users normally use on the copyboard glass and execute the following item;
SCAN > READER > FUNCTION > CCD > DFWLVL1
: Read the white level in BOOK mode. (Check the transparency of the glass for BOOK mode.)
2. Set a paper that users normally use and execute the following item;
SCAN > READER > FUNCTION > CCD > DFWLVL2
: Read the white level in DF mode (stream reading).
(Check the transparency of the glass for stream reading.)
(Read the both sides of chart.)
Reading the face: Calculate DFTAR-R
NOTE:
Be sure to execute these two items (DF-WLVL1/DF-WLVL2) simultaneously.
● #SCAN> READER> FUNCTION> CCD> DF-WLVL2
ADF white level adjustment (platen board cover scan/stream reading scan)
1. Place a paper that users normally use on the copyboard glass and execute the following item;
SCAN > READER > FUNCTION > CCD > DFWLVL1
: Read the white level in BOOK mode. (Check the transparency of the glass for BOOK mode.)
2. Set a paper that users normally use and execute the following item;
SCAN > READER > FUNCTION > CCD > DFWLVL2
: Read the white level in DF mode (stream reading).
(Check the transparency of the glass for stream reading.)
(Read the both sides of chart.)
Reading the face: Calculate DFTAR-R
NOTE:
Be sure to execute these two items (DF-WLVL1/DF-WLVL2) simultaneously.
● #SCAN> READER> FUNCTION> CCD> DF-WLVL3
ADF white level adjustment (platen board cover scan)
NOTE:
Scan a blank sheet on the platen and adjust the white level.
● #SCAN> READER> FUNCTION> CCD> DF-WLVL4
ADF white level adjustment. (DF scan)
NOTE:
Scan a blank sheet in stream reading mode and adjust the white. level.
● #SCAN> READER> FUNCTION> CLEAR> R-CON
Clearing of the backup area for the reader in the main controller.
Clear the backup area for the reader in the main controller.
● #SCAN> READER> FUNCTION> MISC-R> SCANLAMP
The test checks to see if the scanning lamp is on or not.
Execute the when replacing the scanning lamp.
● #SCAN> READER> OPTION> BODY> SENS-CNF
Setting of the document detection sensor placement.
The setting of original detection size is selected between AB and inch configuration in the book mode.
0: AB configuration
8. Service Mode
258
Содержание imageRUNNER 2520 Series
Страница 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 16: ...Product Overview 1 Product Lineup 7 Features 10 Specifications 11 Name of Parts 15 Operation 18 ...
Страница 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Страница 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Страница 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Страница 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Страница 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Страница 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Страница 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Страница 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Страница 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Страница 223: ...Jam Code Main Unit 550 sheet 1st cassette model S1 S5 S7 S19 S12 S42 S40 7 Error Jam Alarm 213 ...
Страница 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Страница 314: ...Example of report display 8 Service Mode 304 ...
Страница 387: ...APPENDICES Service Tools 378 General Circuit Diagram 379 ...