NOTE:
Be sure to enter the value on service label when replacing the CCD unit.
Be sure to enter the numeric value on copyboard glass when replacing the copyboard glass.
If changing the setting value of this item, be sure to write down the changed value on the service label.
● #SCAN> READER> ADJUST> CCD> W-PLT-Y
White label data (Y) entry with standard white plate
This item must not be normally used.
NOTE:
Be sure to enter the value on service label when replacing the CCD unit.
Be sure to enter the numeric value on copyboard glass when replacing the copyboard glass.
If changing the setting value of this item, be sure to write down the changed value on the service label.
● #SCAN> READER> ADJUST> CCD> W-PLT-Z
White label data (Z) entry with standard white plate.
Execute this mode only when necessary. Do not execute it when unnecessary.
NOTE:
Be sure to enter the value on service label when replacing the CCD unit.
Be sure to enter the numeric value on copyboard glass when replacing the copyboard glass.
If changing the setting value of this item, be sure to Note the changed value on the service label.
● #SCAN> READER> ADJUST> CCD> SH-TRGT
Shading target value of the standard white plate (backup)
This item must not be normally used.
● #SCAN> READER> ADJUST> CCD> DFTAR-R
Shading target value (RED) entry when using DF (normal document scanning position)
This item must not be normally used.
● #SCAN> READER> ADJUST> CCD> DFTAR-G
Shading target value (GREEN) entry when using DF (normal document scanning position)
This item must not be normally used.
● #SCAN> READER> ADJUST> CCD> DFTAR-B
Shading target value (BLUE) entry when using DF (normal document scanning position)
This item must not be normally used.
● #SCAN> READER> ADJUST> CCD> DFTAR-K
Black shading target value when using DF
This item must not be normally used.
In case of image fault (due to chart soil, etc) after executing:
SCAN > READER > FUNCTION > CCD > DFWLVL1/ DF-WLVL2; enter the factory measurement value using this mode.
● #SCAN > READER > ADJUST > PASCAL > OFST-P-K
Density adjustment at test print scanning
Execute offset adjustment for test print scanning signal in PASCAL control at auto gradation correction. (full correction)
● #SCAN> READER> FUNCTION> INSTALL> STRD-POS
Auto adjustment of CCD/CIS reading position in stream reading
When installing the DF, or removing the ADF and reinstalling it.
● #SCAN> READER> FUNCTION> CCD> CCD-ADJ
Gain adjustment of analog processor block
When installing the DF, or removing the ADF and reinstalling it.
Reflect the LED lamp beam on the standard white plate to correct CCD shading.
8. Service Mode
257
Содержание imageRUNNER 2520 Series
Страница 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 16: ...Product Overview 1 Product Lineup 7 Features 10 Specifications 11 Name of Parts 15 Operation 18 ...
Страница 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Страница 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Страница 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Страница 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Страница 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Страница 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Страница 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Страница 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Страница 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Страница 223: ...Jam Code Main Unit 550 sheet 1st cassette model S1 S5 S7 S19 S12 S42 S40 7 Error Jam Alarm 213 ...
Страница 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Страница 314: ...Example of report display 8 Service Mode 304 ...
Страница 387: ...APPENDICES Service Tools 378 General Circuit Diagram 379 ...