There is no function to display the license registration numbers in the main unit.
Therefore, when there is a possibility to restore the license after erasing it, make sure that a user has written down the license
registration number.
When a license option is displayed in Procedure (4), 001 1 is displayed.
The last "1" shows that the license is validated by license authentication.
After the license is erased, the last number is changed to "2".
When the option is standard, the last number shows "3" which means disable for license transfer.
Details about the last number:
1. The function is validated.
2. The function is invalidated, or a license is transferred.
3. The function is invalidated, or the license does not exist.
#E-RDS
■ Configuration
Settings related to e-RDS are described below.
Item
Default
Setting range
Description
E-RDS SWITCH 0
0 or 1
e-RDS OFF/ON setting (0:OFF / 1:ON)When used (ON), the counter infor-
mation and error information are sent to UGW.Default: 0 (OFF)
RGW- AD-
DRESS
URL of UGW Character string length:
129byte (including
NULL, one-byte codes
only)
URL of UGWDefault: URL of actual UGWCharacter string length: 129 bytes
(including NULL, one-byte codes only)
RGW-PORT
443
1-65535
Port No. of UGW Default: 443Setting range: 1 to 65535
CNT-DATE
Setting of the date of sending the counter information to the server (Valid
after input of license).
Set the start date of the schedule to send the counter information to the
server using a third party expansion function of E-RDS.
Refer to the user mode date setting.
(12 digits: YYYYMMDDHHMM)
YYYY: Year MM: Month
DD: Day
HH: Hour
MM: Minute
CNT-INTV
24
1-168 (on a weekly ba-
sis)
Setting of the interval of sending the counter information to the server (Valid
after input of license).
Set the interval of sending the counter information to the server using a third
party expansion function of E-RDS.
COM-TEST
Execution of communication test An attempt is made to connect to UGW,
judges whether connection is successful, and displays "COM- TEST OK" or
"COMTEST NG" as the judgment result.
COM-LOG
Details of communication test result. The log of errors in communication with
UGW is displayed. The error information includes the error occurrence time,
error code, and details of the error.Maximum log count: 5Error information
length: Max. 128 characters (excluding NULL)
SCALLCMP
Repair completion process (call button function) Used when the service
personnel has completed the requested repair.
#REPORT
■ Configuration
The table below lists the kinds of reports that are supported.
8. Service Mode
284
Содержание imageRUNNER 2520 Series
Страница 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Страница 16: ...Product Overview 1 Product Lineup 7 Features 10 Specifications 11 Name of Parts 15 Operation 18 ...
Страница 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Страница 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Страница 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Страница 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Страница 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Страница 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Страница 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Страница 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Страница 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Страница 223: ...Jam Code Main Unit 550 sheet 1st cassette model S1 S5 S7 S19 S12 S42 S40 7 Error Jam Alarm 213 ...
Страница 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Страница 314: ...Example of report display 8 Service Mode 304 ...