E602-1602--
File system could not be initialized normally. (CDS-related)
Detection Description
File system could not be initialized normally
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1612--
Device access error (CDS-related)
Detection Description
Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E602-1613--
Device access error (CDS-related)
Detection Description
Device access error
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
* When this error occurs, the firmware downloaded by the CDS Updater will be lost.
E604-0000--
Insufficient memory capacity
Detection Description
Insufficient memory capacity
Remedy
1. Replace the Main Controller PCB.
E604-0001--
Memory error
Detection Description
Memory required to start PDL cannot be allocated.
Remedy
1. Replace the Main Controller PCB.
E616-0001--
MEAP application is lost.
Detection Description
MEAP application is lost.
Remedy
1. Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main
power.
* The setting is switched to the following after reboot.
• Initial screen setting: Native
• MEAP authentication: Off
• USB-Host setting: Native
• CDS-related: Off
E616-0002--
System error
Detection Description
System error
Remedy
1. Execute Setup > Initialize Menu to initialize NVRAM.
E730-100A--
System error
Detection Description
System error
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
E730-C000--
An error, such as failure in memory retrieval at initialization, occurred.
Detection Description
An error, such as failure in memory retrieval at initialization, occurred.
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
E730-C001--
An error occurred when accessing the controller.
Detection Description
An error occurred when accessing the controller.
Remedy
1. Turning OFF and then ON the main power executes auto recovery.
E730-D000--
An error, such as failure in memory retrieval at initialization, occurred.
Detection Description
An error, such as failure in memory retrieval at initialization, occurred.
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
E730-D001--
System error
Detection Description
System error
Remedy
1. Turn OFF and then ON the power.
2. Replace the Main Controller PCB.
8. Error/Jam/Alarm
202
Содержание imageCLASS LBP325dn
Страница 11: ...Safety Precautions Laser 2 Power Supply Lithium Battery 3 Toner Safety 3 Notes on works 4...
Страница 15: ...Product Overview 1 Product Lineup 6 Features 7 Specifications 8 Parts Name 11...
Страница 127: ...Periodical Service 4 Periodically Replaced Parts 118 Consumable Parts 119 Periodical Service 120...
Страница 130: ...Periodical Service Periodical Service No periodic services are required to this machine 4 Periodical Service 120...
Страница 138: ...1 Place paper on the work space 2 Open the Front Cover Unit 3 Remove the cartridge 5 Parts Replacement and Cleaning 128...
Страница 141: ...5 Remove the Right Cover Unit 5 Parts Replacement and Cleaning 131...
Страница 148: ...Procedure 1 Remove the guide 2 Free the Link Arm 3 Remove the shaft 2x 5 Parts Replacement and Cleaning 138...
Страница 166: ...3 Free the harness 2x 1x 4 Remove the Laser Scanner Unit 4x 1x 5 Parts Replacement and Cleaning 156...
Страница 187: ...Adjustment 6 Actions at Parts Replacement 178...
Страница 189: ...Troubleshooting 7 Test Print 180 Cartridge Log Print 186 Troubleshooting 188 Obtaining Debug Log 190...
Страница 204: ...Error Jam Alarm 8 Overview 195 Error Code 197 Jam code 205 Alarm Code 208...
Страница 219: ...Service Mode 9 Overview 210 Service Mode 214...
Страница 243: ...Installation 10 Installation of the host machine 234...