4
4
4-14
4-14
Parts Replacement and Cleaning Procedure > Main Units (ADF) > Removing the Feed Unit
Parts Replacement and Cleaning Procedure > Main Units (ADF) > Removing the Feed Unit
12) Remove the harness guide.
- Connector 5 pcs.
- Screw 1 pc.
x1
x5
13) Remove the pickup clutch/registration clutch.
"Pickup Clutch/Registration Clutch(CL1/
14) Remove the feed unit.
- Screw 7 pcs.
x7
F-4-28
F-4-29
CAUTION:
When install ADF to a host machine after exchange work, adjustment of eight items is