4
4
4-7
4-7
Parts Replacement and Cleaning Procedure > Parts replacement and cleaning procedure > Removing the Reader Scanner Unit > Procedure
Parts Replacement and Cleaning Procedure > Parts replacement and cleaning procedure > Removing the Reader Scanner Unit > Procedure
CAUTION:
Grease is applied on the 2 Rail Shafts [1] of the Reader Scanner Unit. If you have
touched the grease, be careful not to put it to other parts.
[1]
3) Move the belt [1], and move the Reader Scanner Unit [2] to the cut -off of the Reader Unit.
[2]
[3]
[2]
[1]
4) Loosen the screw to release the tension applied on the belt. After that, remove the belt [1]
from the Reader Scanner Unit [2].
F-4-15
[2]
[1]
Loosen
CAUTION: Holding the Reader Scanner Unit
• Be sure to hold both edges [1].
• Do not touch the PCB [2] and the mirror [3].
[2]
[3]
[1]
[1]
5) Place paper on the Stream Reading Glass, and place the Reader Scanner Unit on it with
its up side down.
F-4-16