Cannon Fitzroy Inbuilt Power Flue | 9
Power flUe installation instrUCtions
485 min
300
1000 MIN
TO CEILING
MASONARY
FIREPLACE
APPLICATION
*1*
*2*
fig 8
485 min
TO CEILING
1000 MIN
THROUGH WALL
APPLICATION
TIMBER or BRICK
*1*
*2*
fig 9
MARK AND CUT HOLE
IN REAR
VER
TICAL
FLOOR TO BE
SMOOTH AND FLAT
WALL OF THE CAVITY
FOR FLUEAND
CONDENSATION DRAIN
fig 10
fig 11
160 DIA FLUE
OPENING
FINISHED
FLOOR
LEVEL
345 mm
600 mm
695 mm
50 mm
GAS
SUPPLY
100 mm
140
20 DIA CONDENSE
DRAIN HOLE
517
517
25
min
383
*1*
*2*
25min
fig 13
Corner wall application
refer to mock fireplace installation for
corner wall application on page 24.
Preparing The Cavity
the power flue heater is a high efficiency unit extract-
ing heat which in other heaters would escape in the flue
gases. Condensate from the flue gases will be produced
from this heater.
a condensate drain on the rear of the heater must be
connected to a hose to drain this condensate out of the
house. this hose must be fitted prior to installation of the
heater into the cavity.
Check the floor of the cavity is smooth, flat and level.
using your template as a guide, mark the flue cutout on
the rear wall of the cavity and cut through from either the
inside or the outside to produce a neat round hole in the
external wall.
to make a template, use a sheet of stiff cardboard or
(mdf) medium density fibre board cut to represent the rear
of the heater. Mark a vertical centre line and an appro-
priate circle 345mm from the bottom indicating the flue
position cut out. refer
FIG 11
.
two lengths of flexible aluminium hose is supplied with
the heater. these hoses can be stretched to 1 m lengths.
Place a liberal amount of silicon sealant to the inside of
the flexible flue pipe which is to be mounted onto the
flue outlet.
Slip the flexible aluminium hose over the flue outlet with a
hose clamp, tighten the hose clamp to ensure the hose
is securely attached to the flue outlet.
the flexible aluminium hose is attached to the air inlet in
the same manner, however there is no need to apply the
silicon sealant on the air inlet.
Secure condensate tube to drain using supplied clamp.
*1* For any horizontal application top hat section
can be removed.
*2* Condensation drain must have sufficient fall
to provide adequate drainage ensure no water
traps occur in drain.
fig 12
air inlet
flue outlet
Condensate