background image

Cannon Fitzroy Inbuilt Power Flue | 3

8.   If removed, the glass window must be put back onto 

the unit prior to operating the heater.

9.   Installation and repairs should be performed by a 

licensed service person only, refer to back of brochure 
for service number.

10.  For installation into a non-combustible fireplace, i.e 

masonry or brick or into a mock fireplace, i.e. timber 
or plasterboard, the chimney and base should be  
of sound construction.

Note: when installing into a mock fireplace a  
mock fireplace installation kit must be used. 

11.  testing the effectiveness of the flue. before testing the 

flue confirm air vents are unobstructed. If an exhaust 
fan or other heating appliances are present switch 
them on. this is to test that there is no interaction 
between the Cannon heater and other appliances.

 

 Refer to Australian Standard Gas Installations AS 5601.
For ‘air movement not to affect appliance’ see clause 5.3.1. 
For ‘air supply to appliance’ see clause 5.4.1. 
For ‘ventilation requirements’ see clause 5.4.3.

12.  the appliance should be inspected prior to use, 

with regular inspections (annually) to be made by a 
licensed service person. It is important that circulating 
air passageways of the appliance be kept clean, dirt 
and lint free, for a safe and efficient operation of  
the heater. 

13.  On first lighting your heater a smell may occur due to 

its new condition. this is quite normal and will disap-
pear after a few hours use at the maximum  
control position.

Important: When this heater is operating the mesh 
guard/glass front is hot. The mesh guard, or glass 
front is fitted to this appliance to reduce the risk of 
fire or injury from burns and no part of it should be 
permanently removed. For protection of young chil-
dren or the infirm, a secondary guard is required.

this appliance meets the following standards: 
Standards australia  
aS/nzS 3100 
aS 5601 
aS 4553:2008

safety warnings

Please read this manual before installing and using  
the heater.

Safety Warnings

1.   Improper installation, adjustment, alteration, service 

or maintenance can cause injury or property damage. 
refer to the sections of this manual for correct proce-
dures, or consult with place of purchase, a licensed 
plumber, a gas supplier or the CannOn distributor 
listed in this manual.

2.   Install the heater only in locations that are referred to 

in the installation instructions. Do not build the heater 
into bookcases, walls or enclosures (combustible 
materials) without the use of a Mock Fireplace kit.

3.   Due to high temperatures the room heater should be 

located out of traffic and away from: 
Furniture and draperies 
Combustible materials 
gasoline and other flammable liquids

   Do not place clothing or other flammable  

material on or near the heater.

4.   Keep curtains*, clothes, furniture and other  

flammable materials at least 900mm from front  
and sides of heater. 
*  at the owner’s discretion curtain clearance can  

be less than 900mm as long as they are restrained 
from the front, top and sides of the heater.  
the manufacturer takes no responsibility if curtain 
clearance is less than 900mm and not restrained.

5.   Children and adults should be alerted to the hazard 

of high surface temperature and should take care to 
avoid burns or clothing ignition.

   This appliance is not intended for use by  

persons (including children) with reduced  
physical, sensory or mental capabilities or lack 
of experience and knowledge, unless they have 
been given supervision or instruction concern-
ing use of the appliance by a person responsible 
for their safety. Children should be supervised to 
ensure that they do not play with the appliance.

6.   never attempt to burn paper or any other material in 

the heater.

7. 

 Do not

 place articles on or against this appliance.

   

Do not

 use or store flammable materials near 

this appliance.

   

Do not

 spray aerosols in the vicinity of this 

appliance while it is in operation

 

Do not

 modify this appliance. 

Содержание Fitzroy Inbuilt Power Flue

Страница 1: ...Flue Instruction Manual Please read this manual before installing and using this heater Please leave instruction manual with the owner Distributor This appliance is designed manufactured and distribut...

Страница 2: ...of this warranty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or man...

Страница 3: ...S 3100 AS 5601 AS 4553 2008 Safety Warnings Please read this manual before installing and using the heater Safety Warnings 1 Improper installation adjustment alteration service or maintenance can caus...

Страница 4: ...OFF button once to restart the heater during this time Wait at least 20 seconds before attempting to turn the heater on OperatiON ON OFF LOW HIGH MEDIUM FIG 2 FIG 1 If there is an interruption to the...

Страница 5: ...FLUEWFX Versatility and flexibility are key components of our instal lation options Install in a shallow recess or an existing fireplace elegant spacers will eliminate any size discrep ancies To enhan...

Страница 6: ...lectronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Minimum cavity Height Dimensions 605 mm Width 700 mm Depth 485 mm Optional accessories Glass front Remote thermo...

Страница 7: ...TER IS FAN ASSISTED SEE COLUMN HIGHLIGHTED a Below eaves balconies and other projections Appliances up to 50 MJ hr input 300 200 Appliances over 50 MJ hr input 500 300 b From the ground above a balcon...

Страница 8: ...Ensure that the combustion air opening under the heater is not obstructed Ensure the minimum clearances to combustible materials are maintained during installation including adequate space for the pr...

Страница 9: ...level Using your template as a guide mark the flue cutout on the rear wall of the cavity and cut through from either the inside or the outside to produce a neat round hole in the external wall To mak...

Страница 10: ...8 Fitment Of Flexible Pipes To Flue Terminal The flexible tubing is now fully extended out of the hole in the wall 1 Cut the tubing so that 20mm is extending past the wall opening 2 Fit the stainless...

Страница 11: ...liance is designed to operate on 240V AC power supply Failure to operate unit at correct supply voltage may create unsafe conditions The heater is supplied with a flexible power cord with a plug fitte...

Страница 12: ...er glass making sure not to over tighten the screws 4 Reconnect switch loom to the fascia switch set 5 Replace the fascia GAS CONNECTION FIG 24 FIG 25 FIG 27 FIG 26 1 Push the gas inlet access plate i...

Страница 13: ...w control to give a pressure reading of 0 4 kPa for Natural Gas and 1 1 kPa for LPG Turn clockwise to increase pressure and anticlockwise to decrease pressure Refer FIG 33 5 Remove spanner and screwdr...

Страница 14: ...r to fault codes on page 17 General 1 Service work to be carried out by an authorised service person only 2 Unplug from wall socket or turn off power at main switchboard if heater is hard wired 3 Alwa...

Страница 15: ...m Check for gas tightness For log placement refer page 12 of this manual To Replace The Combustion Fan Fig 36 The Combustion Fan is accessed from the rear of the heater Therefore to replace the combus...

Страница 16: ...HIGH FAN SHEATHED HIGH TEMP DATA CABLE SWITCH BLUE 4 WAY 2 WAY 6 WAY 3 WAY EARTH RED 1 WAY C ROOM FAN F3594 240 V MAINS PLUG BROWN BLUE MODULATING VALVE F3691 COILS FLAME SENSOR SPARK ELECTRODE IGNITI...

Страница 17: ...r has attempted to light however it did not sense flame within the allowed time Check the gas supply to the unit is not switched off Check the gas pressures Check the flame and spark electrode connect...

Страница 18: ...fan for dust build up and lint Check that the room air fan is spinning Check that the pressure tubes are connected correctly and not pinched or kinked The black tube should run from the black side of...

Страница 19: ...Cannon Fitzroy Inbuilt Power Flue 19 Notes...

Страница 20: ...mpliance Certificate No Installed by COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all the...

Отзывы: