background image

4 | Cannon Fitzroy Inbuilt Power Flue

Operating Instructions

Plug the power cord into the wall socket and turn on the 
power to the heater (

FIG 1

). alternatively, switch on the 

isolation switch and circuit breaker at the main switch-
board if the heater has fixed wiring. refrain from using  
an extension cord. 
user controls 

FIG 2

.

When there is power available to the heater and it is in 
the OFF or Standby mode, a red leD located inside the 
On/OFF button will flash twice and will extinguish after 
approximately 3 seconds and then repeat this cycle 
continuously.
to turn the heater On press the On/OFF button once.

•   The LED will illuminate and an audible beep will sound 

but there will be approximately 5 seconds delay 
before the ignition system commences. On success-
ful ignition the heater will operate on low Fire and 
low Fan for approximately 3 minutes then will switch 
to selected setting (if already chosen, otherwise will 
switch to Medium settings automatically).

•   The LED will extinguish approximately 30 seconds 

following the ignition startup.

•   Select the desired heating level by pressing the LOW, 

MeDIuM or HIgH button once as required.

•   LOW is LOW heat and LOW speed fan. HIGH is HIGH 

heat and HIgH speed fan.

•   To turn the heater OFF press the ON/OFF button 

 

once. an audible beep will sound twice to indicate 
the heater is off. the burner will extinguish but the fan 
will continue to operate for approximately 3 minutes. 
remember that the fan will continue to operate for 
approximately 3 minutes after the OFF button has 
been pressed but you can turn the heater On again 
without having to wait for the fan to stop operating.

•   If the ignition system fails to ignite or keep the burner 

alight, the system will beep 4 times and go into 
safe shutdown mode. It will beep 4 times every 30 
seconds to alert you to the fact. Press the On/OFF 
button once to restart the heater during this time. 
Wait at least 20 seconds before attempting to turn the 
heater on. 

oPeration

ON / OFF

LOW

HIGH

MEDIUM

fig 2

fig 1

•   If there is an interruption to the power supply the 

heater will fail safely and switch off. When the power 
supply has been restored adopt the 20 seconds  
waiting rule before turning the heater On.

Cleaning

all cleaning should be carried out when the heater is 
cold. normally the heater should only need wiping with a 
lint-free damp cloth. any stubborn stains can be removed 
with a nonabrasive spray on cleaner. If an abrasive 
cleaner is used the paint finish will be damaged. 
For heaters fitted with the glass front: all cleaning should 
be carried out when the heater is cold. Clean the outer 
glass with a mild liquid or spray on glass cleaner. Do not 
use harsh abrasive cleaners or sharp metal scrapers to 
clean the heater glass front since they can scratch the 
surface, which may result in shattering of the glass.
Internally the heater should only be cleaned by an  
authorised service person.  
If your heater requires attention contact your supplier  
or an authorised service person.

Flame Characteristics 

the heater flame should be stable, not lifting from the 
burner. the logs should glow after approximately 15 
minutes operation on HIgH setting. 
the heater is a fuel effect unit and is designed to  
operate with luminous flames and may exhibit slight 
carbon deposit on the logs. If there is any excess carbon 
build-up on logs, or the burner flame is unstable, contact 
Sampford IXl in your state. 

Important
The appliance should be inspected before use and 
at least annually by an authorised service person. 
More frequent cleaning may be required due to  
excessive lint build-up from carpeting, bedding  
materials, pet hair, etc.
It is imperative that control compartments, burners 
and circulating air passage ways of the appliance 
be kept clean.
Do not use this fire if the glass is cracked or with 
the safety screen removed.
Do not use fire with broken or missing logs.

Содержание Fitzroy Inbuilt Power Flue

Страница 1: ...Flue Instruction Manual Please read this manual before installing and using this heater Please leave instruction manual with the owner Distributor This appliance is designed manufactured and distribut...

Страница 2: ...of this warranty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or man...

Страница 3: ...S 3100 AS 5601 AS 4553 2008 Safety Warnings Please read this manual before installing and using the heater Safety Warnings 1 Improper installation adjustment alteration service or maintenance can caus...

Страница 4: ...OFF button once to restart the heater during this time Wait at least 20 seconds before attempting to turn the heater on OperatiON ON OFF LOW HIGH MEDIUM FIG 2 FIG 1 If there is an interruption to the...

Страница 5: ...FLUEWFX Versatility and flexibility are key components of our instal lation options Install in a shallow recess or an existing fireplace elegant spacers will eliminate any size discrep ancies To enhan...

Страница 6: ...lectronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Minimum cavity Height Dimensions 605 mm Width 700 mm Depth 485 mm Optional accessories Glass front Remote thermo...

Страница 7: ...TER IS FAN ASSISTED SEE COLUMN HIGHLIGHTED a Below eaves balconies and other projections Appliances up to 50 MJ hr input 300 200 Appliances over 50 MJ hr input 500 300 b From the ground above a balcon...

Страница 8: ...Ensure that the combustion air opening under the heater is not obstructed Ensure the minimum clearances to combustible materials are maintained during installation including adequate space for the pr...

Страница 9: ...level Using your template as a guide mark the flue cutout on the rear wall of the cavity and cut through from either the inside or the outside to produce a neat round hole in the external wall To mak...

Страница 10: ...8 Fitment Of Flexible Pipes To Flue Terminal The flexible tubing is now fully extended out of the hole in the wall 1 Cut the tubing so that 20mm is extending past the wall opening 2 Fit the stainless...

Страница 11: ...liance is designed to operate on 240V AC power supply Failure to operate unit at correct supply voltage may create unsafe conditions The heater is supplied with a flexible power cord with a plug fitte...

Страница 12: ...er glass making sure not to over tighten the screws 4 Reconnect switch loom to the fascia switch set 5 Replace the fascia GAS CONNECTION FIG 24 FIG 25 FIG 27 FIG 26 1 Push the gas inlet access plate i...

Страница 13: ...w control to give a pressure reading of 0 4 kPa for Natural Gas and 1 1 kPa for LPG Turn clockwise to increase pressure and anticlockwise to decrease pressure Refer FIG 33 5 Remove spanner and screwdr...

Страница 14: ...r to fault codes on page 17 General 1 Service work to be carried out by an authorised service person only 2 Unplug from wall socket or turn off power at main switchboard if heater is hard wired 3 Alwa...

Страница 15: ...m Check for gas tightness For log placement refer page 12 of this manual To Replace The Combustion Fan Fig 36 The Combustion Fan is accessed from the rear of the heater Therefore to replace the combus...

Страница 16: ...HIGH FAN SHEATHED HIGH TEMP DATA CABLE SWITCH BLUE 4 WAY 2 WAY 6 WAY 3 WAY EARTH RED 1 WAY C ROOM FAN F3594 240 V MAINS PLUG BROWN BLUE MODULATING VALVE F3691 COILS FLAME SENSOR SPARK ELECTRODE IGNITI...

Страница 17: ...r has attempted to light however it did not sense flame within the allowed time Check the gas supply to the unit is not switched off Check the gas pressures Check the flame and spark electrode connect...

Страница 18: ...fan for dust build up and lint Check that the room air fan is spinning Check that the pressure tubes are connected correctly and not pinched or kinked The black tube should run from the black side of...

Страница 19: ...Cannon Fitzroy Inbuilt Power Flue 19 Notes...

Страница 20: ...mpliance Certificate No Installed by COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all the...

Отзывы: