16 | Cannon Fitzroy / Canterbury Inbuilt
serViCe instruCtions (Do not MoDify this aPPlianCe)
To Replace The Gas And Fan Controller
1. remove the fascia. refer to page 11 of the
installation booklet
2. Disconnect the plugs on box.
3. remove the screw retaining the bracket
4. replace the control box
5. Check and re-set gas pressures.
To Replace The Burner And Spark/Sense Electrodes
1. remove the logs from the burner chamber.
2. remove the burner chamber front inspection panel,
4 screws.
3. Disconnect the 16mm nut at the inlet of the
injector.
4. Disconnect the spark and sense electrodes from the
ignition module.
5. remove the burner fixing brackets (2) from the
left and right hand side of the burner. lift the burner
assembly upward and carefully remove from the
burner chamber.
6. replace in reverse order, checking correct location of
spark/sense electrodes. Spark gap between electrode
and spark plate is 6 - 8 mm. Check for gas tightness.
For log placement refer page 13 of this manual.
To Replace Type “X”Cord
Contact Sampford IXl service department.
fig 33