12 | Cannon Fitzroy / Canterbury Inbuilt
Electrical Connection
this appliance is designed to operate on 240v aC power
supply. Failure to operate unit at correct supply voltage
may create unsafe conditions.
the heater is supplied with a flexible power cord with
a plug fitted. a 10 amp power point (socket) must be
located within 1.5m of the heater. For installations where
the power point is located outside of the enclosure,
locate the power cord in the fascia cut out on the left or
right hand side as required.
For a power supply connection located inside the
enclosure run the power cord through the cord access
located on the rear panel by pushing the cord access
plate from the bottom. the rubber grommet that is fitted
over the cord must be located correctly in the cut out of
the cord access plate. refer
FIG 18
.
restore the cord access plate to the original position
and seal with an appropriate removable material, this is
especially important when the installation is in a chimney
with no flue fitted to eliminate the possibility of any leak-
age of flue products into the room.
A suitable double
pole isolation switch must be installed externally for
servicing or emergency shut down of the heater.
all fixed wiring must be installed by a suitably
qualified person and comply to the appropriate
electrical wiring rules and gas installation standards.
eleCtriCal ConneCtion
sealing the fasCia
all gaps between heater case and fireplace are to be
sealed. Seal with foam tape around top and sides of
heater flange as required. (Do not apply sealing product
to fascia). Seal with fibreglass between bottom of heater
case and base of fireplace.
refer
FIG 19
.
DO NOT SEAL WITH SILICON
If using a spacer to compensate for lack of
chimney depth ensure the tape is placed on
the outer rim of the spacer flange. refer
FIG 20
.
fig 19
Sealing tape to be
applied onto flanges of
rear of front surround
so as to seal against
fireplace brick wall
Sealing tape
fig 20
Sealing tape applied
to edge of spacer to
seal against fireplace
fig 18
grommet