Cannon Fitzroy / Canterbury Inbuilt | 11

fitzroy inbuilt fasCia reMoVal

Canterbury inbuilt fasCia reMoVal

1.   remove the wire mesh grille by gently lifting it 

upwards and then outwards. Similarly remove a fitted 
glass kit by also gently lifting it upwards and then 
outwards.

2.   remove 4 M5 screws fixing the fascia assembly to the 

heater body. bring the bottom of the fascia towards 
you gently to partly disengage it from the body of the 
heater. after it has been disengaged gently lift it up 
vertically to completely disengage it from the body of 
the heater. refer 

FIG 10

 & 

FIG11

.

 Inner Glass Removal For Both FITZIB & CANTIB 

to remove the inner glass loosen off all the clamp screws 
and completely remove the one vertical side.  
try not to touch the front surface of the glass. to avoid 
finger marks use suitable cloth. remove the glass by  
sliding the glass sideways out of the clamp and then  
lifting out from the bottom. Place the glass in a safe  
position for refit later.

fig 10

fig 15

fig 12

fig 16

fig 13

fig 17

fig 14

fig 11

to fully remove the 
fascia, unclip the switch 
cable from the cable 
connector on the PCb 
and unclip the cable from 
the clipping points on  
the rear of the fascia.

1.   to remove the inner fascia assembly undo two screws 

in the upper flange as indicated in 

FIG 12

. remove 

the inner fascia assembly by holding the glass 
surround and firmly pull it towards you. refer 

FIG 13

.

2.   remove the lower front cover by unscrewing two M5 

screws through the air intake slots. refer 

FIG 14

 unit 

is fitted with electronic swtiches ensure that the cable 
cannot be trapped when the heater is installed.

3.   to remove the front heater surround undo two screws 

(one either side) from the bottom flange of  
the front panel as indicated in 

FIG 15

.

4.   remove the surround by pulling the lower section 

towards you gently to partly disengage it from the 
body of the heater, then gently lift it vertically to 
completely disengage it. refer 

FIG 16

.

5.   to fully remove the fascia, unclip the switch cable  

from the PCb connector and unclip the cable from  
the clipping points. the cable is routed through a 
plastic grommet which will have to be removed from 
the base plate. refer 

FIG 17

.

grommet

Содержание CANTERBURY

Страница 1: ...n Manual Please read this manual before installing and using this heater Please leave instruction manual with the owner Distributor This appliance is designed manufactured and distributed by Tel 1300 727 421 Fitzroy Canterbury ...

Страница 2: ...original purchase We will at our option and subject to the terms of this warranty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or manufacturing However this warranty does not cover any consumables if any The purchaser must present the original purchase receipt to us wh...

Страница 3: ... no part of it should be permanently removed For protection of young chil dren or the infirm a secondary guard is required This appliance meets the following standards Standards Australia AS NZS 3100 AS 5601 AS 4553 2008 Safety Warnings Please read this manual before installing and using the heater Safety Warnings 1 Improper installation adjustment alteration service or maintenance can cause injur...

Страница 4: ...N OFF button once to restart the heater during this time Wait at least 20 seconds before attempting to turn the heater on OperatiON ON OFF LOW HIGH MEDIUM FIG 2 FIG 1 If there is an interruption to the power supply the heater will fail safely and switch off When the power supply has been restored adopt the 20 seconds waiting rule before turning the heater ON Cleaning All cleaning should be carried...

Страница 5: ...inless steel Canterbury mesh kit CANTIBMG B Remote Thermostat RTKIT Versatility and flexibility are key components of our instal lation options If installed into a shallow recess or an existing fireplace elegant spacers will eliminate any size discrepancies To enhance your Cannon s appearance add a decorative 3 or 4 sided surround Every Cannon heater brings you the optional convenience of being co...

Страница 6: ...an 3 speed Ignition Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Minimum cavity dimensions Height 605 mm Width 700 mm Depth 405 mm Optional accessories Glass front Remote thermostat Spacer kit 3 sided surround 4 sided surround Console kit Overall dimensions Refer to FIG 3 For installation into a non combustible fireplace ie masonry or brick Please Note W...

Страница 7: ...ssure at burner high setting Natural gas 0 75 kPa Propane gas 2 65 kPa Gas regulator Integral part of controller Min inlet pressure 1 13 kPa NG 2 75 kPa Propane Fan 3 speed Ignition Electronic direct spark Power requirement 240 VAC 10 Amp Power consumption 90 VA maximum Minimum cavity dimensions Height 605mm Width 700mm Depth 385mm Optional accessories Safety mesh guard Remote thermostat Spacer ki...

Страница 8: ...nstructions Overview 1 This appliance is to be installed by an authorised serv ice person only 2 This appliance shall be installed in accordance with the manufacturer s installation instructions local gas fitting regulations municipal building codes electrical wiring regulations and AS5601 the Australian Standard for gas installations 3 Remove the heater from the carton and remove the four transit...

Страница 9: ... 655 mm 600 mm Ceiling Mantle 300 mm min clearance 900 mm min clearance Rear wall 380 mm 1000 mm min clearance 50 mm clearance For installations in non combustible enclosures For installations in non combustible enclosures Mock Fireplace Opening Combustible materials Fitzroy Inbuilt Canterbury Inbuilt Max Min Max Min Height 650 mm 630 mm 654 mm 630 mm Width 780 mm 731 mm 790 mm 731 mm Depth 600 mm...

Страница 10: ...bends FIG 9 Be careful Installing a flue on the shorter wall may subject it to down draughts or reverse air flows through the heater which can be difficult to find a solution to Always adopt correct flue design practices In windy locations consider installation of a powerflue version heater or at least an anti down draught cowl to reduce any flue operation problems The heater has been tested and s...

Страница 11: ... FIG 16 FIG 13 FIG 17 FIG 14 FIG 11 To fully remove the fascia unclip the switch cable from the cable connector on the PCB and unclip the cable from the clipping points on the rear of the fascia 1 To remove the inner fascia assembly undo two screws in the upper flange as indicated in FIG 12 Remove the inner fascia assembly by holding the glass surround and firmly pull it towards you Refer FIG 13 2...

Страница 12: ...al this is especially important when the installation is in a chimney with no flue fitted to eliminate the possibility of any leak age of flue products into the room A suitable double pole isolation switch must be installed externally for servicing or emergency shut down of the heater All fixed wiring must be installed by a suitably qualified person and comply to the appropriate electrical wiring ...

Страница 13: ...r glass making sure not to over tighten the screws 4 Reconnect switch loom to the fascia switch set 5 Replace the fascia GAS CONNECTION FIG 22 FIG 23 FIG 25 FIG 24 1 Push the gas inlet access plate into the heater cabinet and slide the heater into the fireplace ensuring that the gas inlet pipe is fed through the hole located at the rear right hand side of the heater at the bottom Refer FIG 26 2 Wi...

Страница 14: ...control to give a pressure reading of 0 4 kPa for Natural Gas and 1 1 kPa for LPG Turn clockwise to increase pressure and anticlockwise to decrease pressure Refer FIG 31 5 Remove spanner and screwdriver Switch from high to low to ensure settings are correct 6 Switch heater off and remove the manometer tube Tighten pressure test point by turning the captive screw fully clockwise 7 Replace plastic c...

Страница 15: ...an is spin ning refer to fault codes on page 18 General 1 Service work to be carried out by an authorised service person only 2 Unplug from wall socket or turn off power at isolation switch if heater is hard wired 3 Always shut off the gas supply and ensure that the heater is cool before commencing any service operations 4 Always check for gas soundness after servicing To Replace The Inner Glass R...

Страница 16: ...move the burner chamber front inspection panel 4 screws 3 Disconnect the 16mm nut at the inlet of the injector 4 Disconnect the spark and sense electrodes from the ignition module 5 Remove the burner fixing brackets 2 from the Left and Right hand side of the burner Lift the burner assembly upward and carefully remove from the burner chamber 6 Replace in reverse order checking correct location of s...

Страница 17: ... ON OFF LOW BRN LOW FAN MED BRN MED FAN HIGH BRN HIGH FAN SHEATHED HIGH TEMP DATA CABLE SWITCH BLUE 4 WAY 2 WAY 6 WAY 3 WAY EARTH RED 1 WAY C ROOM FAN F3594 240 V MAINS PLUG BROWN BLUE MODULATING VALVE F3691 COILS FLAME SENSOR SPARK ELECTRODE IGNITION MODULE F3833 PRESSURE SWITCH F3327 ROOM AIR FAN NO C 2 WAY 4 WAY 2 WAY NC RED RED BLUE RED EARTH F3835 A CONTROL MODULE F3828 ...

Страница 18: ... of the pressure switch and to the top tapping on the venturi Make sure that the pressure switch wires are connected correctly One wire should be to C Common and the other should be to NO Normally Open If it still doesn t work after checking the above change the pressure switch To check the operation of the heater s electrical system you will require a digital multimeter with the functions to meas...

Страница 19: ...de of the pressure switch to the bottom tapping on the fan venturi The clear tube should go from the light side of the pressure switch and to the top tapping on the venturi Make sure that the pressure switch wires are connected correctly One wire should be to C Common and the other should be to NO Normally Open If it still doesn t work after checking the above change the pressure switch 2 8 Room f...

Страница 20: ...led Compliance Certificate No Installed by COPY RATING LABEL HERE Don t Risk Your Appliance Warranty Only a licensed person will give you a compliance certificate showing that the work complies with all the relevant standards And only a licensed person will have insurance protecting their workmanship for 6 years So make sure you use a licensed person to install this appliance and ask for your comp...

Отзывы: