Cannon Fitzroy / Canterbury Inbuilt | 7
inbuilt: Canterbury sPeCifiCations
Cannon Canterbury inbuilt
fig 4 front View and side View
298 mm
850 mm
690 mm
700 – 790 mm
34 mm
125 mm
65
5
m
m
60
0
mm
Ceiling
Mantle 300 mm min clearance
900 mm min
clearance
Rear wall
380 mm
1000 mm min clearance
50 mm
clearance
gas type
natural or Propane gas, as
indicated on data label
gas consumption
26 MJ/hr input
energy output
5.98 kW / 21.45 MJ/hr
energy star rating
4.05 stars
Heater type
gas space heater approved to
aS4553:2008
Operating pressure
(at burner high setting)
natural gas: 0.75 kPa
Propane gas 2.65 kPa
gas regulator
Integral part of controller
Min. inlet pressure
1.13 kPa (ng)
2.75 kPa (Propane)
Fan
3 speed
Ignition
electronic direct spark
Power requirement
240 vaC 10 amp
Power consumption
90 va maximum
Minimum cavity
dimensions
Height 605mm*
Width 700mm
Depth 385mm
Optional accessories
• Safety mesh guard
• Remote thermostat
• Spacer kit
• 3 sided surround
• 4 sided surround
• Console kit
Overall dimensions
refer to
FIG 4
*For installation into a non-combustible fireplace, ie:
masonry or brick.
Please note:
• When installing into a mock fireplace a mock
fireplace installation kit must be used.
• The data label is located in the fan chamber. Access
by removing fascia.