2.  PROGRAM THE INTERFACE 

 

Chapter 2: PROGRAM THE INTERFACE 

 

2-1 Introduction 

2-2 Program the Interface - Plug and Play 

 

2-2-1 RS232 serial port 

 

2-2-2 USB PC or Macintosh Keyboard 

 

2-2-3 USB HID 

 

2-2-4 USB Serial 

2-3 Keyboard Country Layout 

 

2-3-1 Keyboard Countries 

2-4 Keyboard Style 

2-5 Keyboard Conversion 

2-6 Control Character Output 

2-7 Keyboard Modifiers 

2-8 RS232 Modifiers 

 

2-8-1 Baud Rate 

 

2-8-2 RS232 Word Length: Data Bits, Stop Bits, and Parity 

 

2-8-3 RS232 Receiver Time-Out 

 

2-8-4 RS232 Handshaking 

 

2-8-5 RS232 Timeout 

 

2-8-6 XON/XOFF 

 

2-8-7 ACK/NAK 

 

2-8-8 RS232 Stop Mode 

Содержание CM-2D002

Страница 1: ...2D Barcode Scanner Module User Manual Ver 1 2 Copyright March 15 2018 All rights reserved...

Страница 2: ...d Modifiers 32 2 8 RS232 Modifiers 34 2 8 1 Baud Rate 34 2 8 2 RS232 Word Length Data Bits Stop Bits and Parity 36 2 8 3 RS232 Receiver Time Out 38 2 8 4 RS232 Handshaking 39 2 8 5 RS232 Timeout 40 2...

Страница 3: ...bile Phone Read Mode 61 3 12 Poor Quality Codes 62 3 12 1 Poor Quality 1D codes 62 3 12 2 Poor Quality PDF Codes 62 3 13 Hands Free Time Out 63 3 14 Reread Delay in Presentation Mode 63 3 15 User Spec...

Страница 4: ...ands 92 5 4 4 Miscellaneous Commands 94 5 5 Data Formatter 97 5 6 Primary Alternate Data Formats 98 Chapter 6 SYMBOLOGIES 99 6 1 All Symbologies 103 6 2 Message Length Description 104 6 3 Codabar 105...

Страница 5: ...9 2 Straight 2 of 5 IATA Message Length 123 6 10 Matrix 2 of 5 124 6 10 1 Matrix 2 of 5 On Off 124 6 10 2 Matrix 2 of 5 Message Length 124 6 11 Code 11 125 6 11 1 Code 11 On Off 125 6 11 2 Check Digit...

Страница 6: ...144 6 19 EAN JAN 8 146 6 19 1 EAN JAN 8 On Off 146 6 19 2 EAN JAN 8 Check Digit 146 6 19 3 EAN JAN 8 Addenda 147 6 19 4 EAN JAN 8 Addenda Required 147 6 19 5 EAN JAN 8 Addenda Separator 148 6 20 MSI 1...

Страница 7: ...6 33 1 Data Matrix On Off 168 6 33 2 Data Matrix Message Length 168 6 33 3 Data Matrix Code Page 169 6 34 Mexicode 170 6 34 1 MaxiCode On Off 170 6 34 2 MaxiCode Message Length 170 6 35 Aztec Code 171...

Страница 8: ...mmand Syntax 190 8 2 1 Serial Command Example 191 8 3 Trigger Commands 193 8 4 Setting the Custom Defaults 194 8 5 Resetting the Custom Defaults 194 8 6 Menu Commands 195 Chapter 9 MAINTENANCE AND TRO...

Страница 9: ...9 1 GET STARTED Chapter 1 GET STARTED 1 1 Reading Techniques 1 2 Setting Custom Default 1 3 Reset the Custom Defaults...

Страница 10: ...is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit To...

Страница 11: ...o save for your custom defaults scan the Save Custom Defaults bar code Set Custom Defaults Save Custom Defaults You may have a series of custom settings and want to correct a single setting To do so j...

Страница 12: ...for most users It resets the scan engine to the custom default settings If there are no custom defaults it will reset the scan engine to the factory default settings Any settings that have not been sp...

Страница 13: ...HID 2 2 4 USB Serial 2 3 Keyboard Country Layout 2 3 1 Keyboard Countries 2 4 Keyboard Style 2 5 Keyboard Conversion 2 6 Control Character Output 2 7 Keyboard Modifiers 2 8 RS232 Modifiers 2 8 1 Baud...

Страница 14: ...ort The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal It also programs a carriage return CR and a line feed LF suffix baud rate and data format as indicated b...

Страница 15: ...the scan engine for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes also adds a CR suffix Default USB Keyboard PC USB Keyboard PC USB keyboard Mac 2 2 3 USB HID Scan the following barco...

Страница 16: ...t If your are using a Windows OS you will need to a driver Apple Machintosh computers recognize the scanner as a USB CDC class device and automatically use a class driver USB serial Note No extra conf...

Страница 17: ...keyboard layout for your country or language As a general rule the following characters are supported but need special care for countries other than the United States 2 3 1 Keyboard Countries United S...

Страница 18: ...18 2 PROGRAM THE INTERFACE Bosnia Brazil Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual...

Страница 19: ...19 2 PROGRAM THE INTERFACE Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Denmark Dutch Netherlands...

Страница 20: ...20 2 PROGRAM THE INTERFACE Estonia Faroese Finland France Gaelic Germany Greek...

Страница 21: ...21 2 PROGRAM THE INTERFACE Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Greek Latin Greek MS Greek Polytonic Hebrew...

Страница 22: ...22 2 PROGRAM THE INTERFACE Hungarian 101 key Hungary Iceland Irish Italian 142 Italy Japan ASCII Kazakh...

Страница 23: ...23 2 PROGRAM THE INTERFACE Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania Lithuania IBM Macedonia...

Страница 24: ...24 2 PROGRAM THE INTERFACE Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal...

Страница 25: ...25 2 PROGRAM THE INTERFACE Romania Russia Russian MS Russian Typewriter SCS Serbia Cyrillic Serbia Latin...

Страница 26: ...26 2 PROGRAM THE INTERFACE Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Sweden...

Страница 27: ...27 2 PROGRAM THE INTERFACE Switzerland French Switzerland German Tatar Turkey F Turkey Q Ukrainian United Kingdom...

Страница 28: ...28 2 PROGRAM THE INTERFACE United Stated Dvorak United States Dvorak left United States Dvorak right United States International Uzbek Cyrillic...

Страница 29: ...Caps Lock key off Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used...

Страница 30: ...All Characters to Upper Case or to abc569gk by scanning Convert All Characters to Lower Case These settings override Keyboard Style selections Note If your interface is a keyboard wedge first scan the...

Страница 31: ...acter for a carriage return is expected the output would display CR instead of the ASCII code of 0D Refer to ASCII Conversion Chart Code Page 1252 Only codes 00 through 1F are converted the first colu...

Страница 32: ...ed DOS mode is a legacy mode and it does not support all keyboard country codes New users should use the Windows mode Refer to ASCII Conversion Chart Code Page 1252 for CTRL X Values Windows Mode Pref...

Страница 33: ...On Turbo Mode Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off Numeric Keypad Mode On Numeric Keypad Mode off Automatic Direct Connect Mode This select...

Страница 34: ...e Baud Rate sends the data from the scan engine to the terminal at the specified rate The host terminal must be set for the same baud rate as the scan engine Default 115200 300 bps 600 bps 1200 bps 24...

Страница 35: ...35 2 PROGRAM THE INTERFACE 19200 bps 38400 bps 57600 bps 115200 bps...

Страница 36: ...tuation select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means o...

Страница 37: ...37 2 PROGRAM THE INTERFACE 7 Data 2 Stop Parity Odd 8 Data 1 Stop Parity Even 8 Data 1 Stop Parity None 8 Data 1 Stop Parity Odd 8 Data 1 Stop Parity Mark...

Страница 38: ...t to wake up the receiver and reset the time out A transaction on the CTS line will also wake up the receiver The receiver takes 300 milliseconds to completely come up Change the RS232 receiver time o...

Страница 39: ...host Two Direction Flow Control The scan engine asserts RTS when it is OK for the host to transmit The host asserts CTS when it is OK for the device to transmit Flow Control with Timeout The scan eng...

Страница 40: ...he inside back cover then scanning Save RS232 Timeout 2 8 6 XON XOFF Standard ASCII control characters can be used to tell the scan engine to start sending data XON XOFF On or to stop sending data XON...

Страница 41: ...NAK is received the last set of bar code data is retransmitted and the scan engine waits for ACK NAK again Turn on the ACK NAK protocol by scanning the ACK NAK On bar code below To turn off the proto...

Страница 42: ...ay 3 5 Manual Trigger Mode 3 5 1 LED Illumination Manual Trigger 3 6 Character Activation Mode 3 6 1 Activation Character 3 6 2 End Character Activation After Good Read 3 6 3 Character Activation Time...

Страница 43: ...SETTINGS 3 16 2D Reread Delay 3 17 Illumination Lights 3 18 Aimer Delay 3 18 1 User Specified Aimer Delay 3 19 Aimer Mode 3 20 Centering 3 21 Multiple Symbols 3 22 No Read 3 23 Video Reverse 3 24 Wor...

Страница 44: ...ower up Beer off scanner Power up Beer on Scanner 3 2 Beep on BEL Character You may wish to force the scan engine to beep upon a command sent from the host If you scan the Beep on BEL On barcode below...

Страница 45: ...triggering Default Trigger Click Off Trigger Click Off Trigger Click on 3 4 Good Read and Error Indicators 3 4 1 Beeper Good Read The beeper may be programmed On or Off in response to a good read Tur...

Страница 46: ...INPUT OUTPUT SETTINGS 3 4 2 Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scan engine emits on a good read Default High Low Medium High Off 3 4 2 Beeper Volume Good...

Страница 47: ...p the scan engine emits on a good read Default Medium Low 1600 Hz Medium 2400 Hz High 4200 Hz 3 4 4 Beeper Pitch Error The beeper pitch codes modify the pitch frequency of the sound the scan engine em...

Страница 48: ...S Medium 3250 Hz High 4200 Hz 3 4 5 Beeper Duration Good Read The beeper duration codes modify the length of the beep the scan engine emits on a good read Default Normal Normal Beep Short Beep 3 4 5 B...

Страница 49: ...the beeper and LED in response to a good read For example if you program this option to have five beeps there will be five beeps and five LED flashes in response to a good read The beeps and LED flash...

Страница 50: ...ive LED flashes in response to an error To change the number of error beeps scan the bar code below and then scan a digit 1 9 bar code and the Save barcode on the Programming Chart inside the back cov...

Страница 51: ...e good read delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save User Specified Good Read Delay Example When set...

Страница 52: ...Trigger If you wish to set the illumination LED brightness scan one of the barcodes below This sets the LED illumination for the scan engine when the trigger is pressed Default High Note The LEDs are...

Страница 53: ...en use Activation Character following to select the character you will send from the host to start scanning Default Off Off On 3 6 1 Activation Character This sets the character used to trigger scanni...

Страница 54: ...haracter Activation After Good Read Do Not End Character Activation After Good Read End Character Activation After Good Read 3 6 3 Character Activation Timeout You can set a timeout for the length of...

Страница 55: ...e scanning Default Off Off On 3 7 1 Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode On the ASCII Conversion Chart Code Page 1252 find t...

Страница 56: ...Out Use this selection to set a time out in milliseconds of the scan engine s trigger when using serial commands to trigger the scan engine Once the scan engine has timed out you can activate the scan...

Страница 57: ...ation Mode Scan one of the bar codes below to set the LED illumination for the scanner when it is in an idle state in Presentation Mode Default On Note If you use one of the lower Idle Illumination se...

Страница 58: ...presentation To set the sensitivity scan the Sensitivity bar code then scan the degree of sensitivity from 0 20 from the inside back cover and Save 0 is the most sensitive setting and 20 is the least...

Страница 59: ...using the Top of Presentation Centering Window Bottom of Presentation Centering Window Left and Right of Presentation Centering Window barcodes In the example below the white box is the centering wind...

Страница 60: ...SETTINGS With Presentation Centering Presentation centering Off Top of Presentation Centering Window Bottom of Presentation Centering Window Left of Presentation Centering Window Right of Presentation...

Страница 61: ...en it is decoded Default CodeGate Off Out ofStand CodeGate Off Out of Stand CodeGate On Out of Stand 3 11 Mobile Phone Read Mode When this mode is selected your scanner is optimized to read bar codes...

Страница 62: ...Default Poor Quality 1D Reading Off Poor quality 1D reading on Poor quality 1D reading off 3 12 2 Poor Quality PDF Codes This setting improves the scanner s ability to read damaged or badly printed PD...

Страница 63: ...hands free mode Scan the Hands Free Time Out bar code then scan the time out duration from 0 300 000 milliseconds from the inside back cover and Save Default 5 000 ms Hand Free Time Out 3 14 Reread D...

Страница 64: ...er Specified Reread Delay If you want to set your own length for the reread delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover th...

Страница 65: ...sh to set a separate Reread Delay for 2D bar codes scan one of the programming codes that follows 2D Reread Delay Off indicates that the time set for Reread Delay is used for both 1D and 2D bar codes...

Страница 66: ...er light The aiming light can be set using Aimer Mode Light On Light off 3 18 Aimer Delay The aimer delay allows a delay time for the operator to aim the scan engine before the picture is taken Use th...

Страница 67: ...l then scan Save Delay Duration 3 19 Aimer Mode This feature allows you to turn the aimer on and off When turning the aimer on there are 2 options Interlaced the aimer is interlaced with the illuminat...

Страница 68: ...Aimer Delay and Centering features the scanner can emulate the operation of older systems such as linear laser bar code scanners If a bar code is not touched by a predefined window it will not be deco...

Страница 69: ...the centering window Scan Centering On then scan one of the following bar codes to change the top and bottom of the centering window Then scan the percent you want to shift the centering window using...

Страница 70: ...ner s trigger If you press and hold the trigger aiming the scanner at a series of symbols it reads unique symbols once beeping if turned on for each read The scanner attempts to find and decode new sy...

Страница 71: ...the No Read symbol is 9C 3 23 Video Reverse Video Reverse is used to allow the scan engine to read barcodes that are inverted The Video Reverse Off barcode below is an example of this type of barcode...

Страница 72: ...ion sensitive For example KIX codes and OCR can misread when scanned sideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented uprigh...

Страница 73: ...73 3 INPUT OUTPUT SETTINGS Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom...

Страница 74: ...l Symbologies 4 1 4 To Clear One or All Prefixes or Suffixes 4 1 5 To Add a Carriage Return Suffix to All Symbologies 4 2 Prefix Selections 4 3 Suffix Selections 4 4 Function Code Transmit 4 5 Interch...

Страница 75: ...sary to build a message string The selections in this chapter are only used if you wish to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared...

Страница 76: ...C twice once to create the leading backslash and then to create the backslash itself Step 5 Scan the 2 digit hex value from the Programming Chart inside the back cover of this manual Step 6 Repeat Ste...

Страница 77: ...x value from the Symbology Chart included in the Symbology Charts for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value from the Programming Chart insid...

Страница 78: ...refix Clear All Prefixes 4 3 Suffix Selections Add Suffix Clear One Suffix Clear All Suffix Example When setting the prefix of all code symbols 99 hex to ABC scan in the following order Add Prefix 9 9...

Страница 79: ...suffix 6 2 4 4 Function Code Transmit When this selection is enabled and function codes are contained within the scanned data the scan engine transmits the function code to the terminal Charts of the...

Страница 80: ...each character of scanned data Scan the Intercharacter Delay barcode below then scan the number of 5ms delays and the Save barcode using the Programming Chart inside the back cover of this manual Pref...

Страница 81: ...arcode using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the 2 digit hex value for the ASCII character that will trigger the delay...

Страница 82: ...rcode below then scan the number of 5ms delays and the Save barcode using the Programming Chart inside the back cover of this manual Interfunction Delays Interfunction Delay To remove this delay scan...

Страница 83: ...ssage Delay bar code below then scan the number of 5ms delays and the Save barcode using the Programming Chart inside the back cover of this manual Intermessage Delay To remove this delay scan the Int...

Страница 84: ...Introduction 5 2 Add a Data Format 5 2 1 Other Programming Selections 5 3 Terminal ID Table 5 4 Data Format Editor Commands 5 4 1 Send Commands 5 4 2 Move Commands 5 4 3 Search Commands 5 4 4 Miscell...

Страница 85: ...fic Terminal ID Actual Code ID Actual Length Specific Terminal ID Actual Code ID Universal Length Specific Terminal ID Universal Code ID Actual Length Specific Terminal ID Universal Code ID Universal...

Страница 86: ...3 digits For example scan 0 0 3 for an AT wedge Note 099 indicates all terminal types Step 4 Code I D In the Symbology Charts find the symbology to which you want to apply the data format Locate the H...

Страница 87: ...ternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts and the bar code data length for the specific data format that you want t...

Страница 88: ...de in the output message all of the characters from the input message starting from current cursor position followed by an insert character Syntax F1xx where xx stands for the insert character s hex v...

Страница 89: ...tput as 1234567890 ABCDEFGHIJ CR F3 Send all characters up to a particular character Include in the output message all characters from the input message starting with the character at the current curs...

Страница 90: ...the current position Syntax F4xxnn where xx stands for the insert character s hex value for its ASCII code and nn is the numeric value 00 99 for the number of times it should be sent Refer to the ASC...

Страница 91: ...F1 0D Move the cursor forward a number of characters command Number of characters to move the cursor Send all characters command Hex value for a CR The data is output as 4567890ABCDEFGHIJ CR F6 Move...

Страница 92: ...message forward for xx character from the current cursor position leaving the cursor pointing to the xx character Syntax F8xx where xx stands for the search character s hex value for its ASCII code Re...

Страница 93: ...hex and character codes Example Remove zeroes at the beginning of bar code data This example shows a bar code that has been zero filled You may want to ignore the zeroes and send all the data that fol...

Страница 94: ...the bar code above Command string FB0120F10D FB 01 20 F1 0D Suppress characters command Number of character types to be suppressed Hex value for a space Send all characters command Hex value for a CR...

Страница 95: ...replacing characters Terminates character replacement Syntax E5 FE Compare characters Compare the character in the current cursor position to the character xx If characters are equal move the cursor...

Страница 96: ...want only data from bar codes that begin with a letter you can use ED to check for the letter Command string EDF10D ED F1 0D Check for a non numeric character command Send all characters command Hex...

Страница 97: ...nd prefixes and suffixes are transmitted Data Format Required Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Any data that does not...

Страница 98: ...switch between these formats Your primary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below...

Страница 99: ...cal PARAF 6 4 7 Full ASCII 6 4 8 Code 39 Code Page 6 5 Interleaved 2 of 5 6 5 1 Interleaved 2 of 5 On Off 6 5 2 Check Digit 6 5 3 Interleaved 2 of 5 Message Length 6 6 NEC 2 of 5 6 6 1 NEC 2 of 5 On O...

Страница 100: ...4 1 UPC A On Off 6 14 2 Convert UPC A to EAN 13 6 14 3 UPC A Check Digit 6 14 4 UPC A Number System 6 14 5 UPC A Addenda 6 14 6 UPC A Addenda Required 6 14 7 UPC A Addenda Separator 6 15 UPC A EAN 13...

Страница 101: ...tabar Expanded 6 23 1 GS1 DatabarExpanded On Off 6 23 2 GS1 DatabarExpanded Message Length 6 24 Codablock A 6 24 1 Codablock A On Off 6 24 2 Codablock A Message Length 6 25 Codablock F 6 25 1 Codabloc...

Страница 102: ...Append 6 35 4 Aztec Code Page 6 36 Chinese Sensible Han Xin Code 6 36 1 Han Xin Code On Off 6 36 2 Han Xin Code Message Length 6 37 Postal Codes 2D 6 37 1 Single 2D Postal Codes 6 37 2 Combination 2D...

Страница 103: ...y a particular symbology scan All Symbologies Off followed by the On symbol for that particular symbology Note Scanner performance may reduce by scanning All Symbologies On Only scan when needed All S...

Страница 104: ...a count of 9 20 characters Min length 09Max length 20 Example Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value other than the minimum and maximum messa...

Страница 105: ...f On Off 6 3 2 Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the barcode You may transmit or not transmit Start Stop characters Default Not to Transmit...

Страница 106: ...th or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar barcodes with a check character and will transmit this character at the end of t...

Страница 107: ...rt character adjacent to a symbol having a D stop character In this case the two messages are concatenated into one with the D charactersomitted Select Require to prevent the scanner from decoding a s...

Страница 108: ...e barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Lengt...

Страница 109: ...6 4 2 Code 39 Start Stop Characters Start Stop characters identify the leading and trailing ends of the barcode You may transmit or not transmit Start Stop characters Default Not to Transmit Transmit...

Страница 110: ...nit only reads Code 39 barcodes with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code...

Страница 111: ...Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer When the scanner encounters a Code 39 bar code...

Страница 112: ...ARAF On Off 6 4 7 Full ASCII If Full ASCII Code 39 decoding is enabled certain character pairs within the bar code symbol will be interpreted as a single character For example V will be decoded as the...

Страница 113: ...ed was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see...

Страница 114: ...eck Digit is set to Validate but Not to Transmit the unit only reads Interleaved 2 of 5 barcodes with a check digit but will not transmit the check digit with the scanned data When Check Digit is set...

Страница 115: ...eaved 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxim...

Страница 116: ...n Check Digit is set to Validate but Not to Transmit the unit only reads NEC 2 of 5 barcodes with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to V...

Страница 117: ...3 NEC 2 of 5 Message Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxim...

Страница 118: ...age Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Mi...

Страница 119: ...scanner stores those Code 93 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in which the bar...

Страница 120: ...using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 6...

Страница 121: ...of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 48 Minimum Default 4...

Страница 122: ...um Message Length 6 9 Straight 2 of 5 IATA two bar start stop Default All Straight 2 of 5 IATA Settings 6 9 1 Straight 2 of 5 IATA On Off On Off 6 9 Straight 2 of 5 IATA two bar start stop 6 9 1 Strai...

Страница 123: ...e barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Minimum Message Lengt...

Страница 124: ...essage Length Scan the barcodes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80...

Страница 125: ...11 1 Code 11 On Off On Off 6 11 2 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits One Check Digit Two Check Digits 6 11...

Страница 126: ...e bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message Leng...

Страница 127: ...license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood products 2 the current recommendation to use Code 128 due to its high degree of security and i...

Страница 128: ...4 Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer When the scanner encounters a Code 128 bar...

Страница 129: ...the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements and scan the value and...

Страница 130: ...the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 Minimum Message Le...

Страница 131: ...AN 13 When UPC A Converts to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front When Not to Convert UPC A is selected UPC A codes are read as UPC A...

Страница 132: ...itted at the end of the scanned data or not Default On On Off 6 14 4 UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the...

Страница 133: ...and 5 Digit Addenda 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off 6 14 6 UPC A Addenda Required When Required is scanned the scanner will only read UPC A bar codes tha...

Страница 134: ...uired 6 14 7 UPC A Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On On Off 6 14...

Страница 135: ...atenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as one symbology Otherwise it transmits the first coupon code it reads If you scan...

Страница 136: ...have both UPC and GS1 DataBar codes you may wish to scan and output only the data from the GS1 DataBar code Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data Default...

Страница 137: ...Off Most U P C bar codes lead with the 0 number system To read these codes use the UPC E0 On selection Default On If you need to read codes that lead with the 1 number system use UPC E1 Default off U...

Страница 138: ...E code to the 12 digit UPC A format Default Off On Off 6 17 3 UPC E0 Addenda Required When Required is scanned the scanner will only read UPC E bar codes that have addenda Default Not Required Requir...

Страница 139: ...from the bar code and the data from the addenda When turned Off there is no space Default On On Off 6 17 5 UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the...

Страница 140: ...g of scanned data To prevent transmission scan Off Default On On Off 6 17 7 UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Dig...

Страница 141: ...141 6 SYMBOLOGIES 5 Digit Addenda Off...

Страница 142: ...8 1 EAN JAN 13 On Off On Off 6 18 2 EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off 6...

Страница 143: ...for both 2 Digit and 5 Digit Addenda 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off 6 18 4 EAN JAN 13 Addenda Required When Required is scanned the scanner will only rea...

Страница 144: ...enda When turned Off there is no space Default On On Off Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code 6 18 6 ISBN Translate Whe...

Страница 145: ...145 6 SYMBOLOGIES Off...

Страница 146: ...19 1 EAN JAN 8 On Off On Off 6 19 2 EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off 6...

Страница 147: ...for both 2 Digit and 5 Digit Addenda 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off 6 19 4 EAN JAN 8 Addenda Required When Required is scanned the scanner will only rea...

Страница 148: ...d 6 19 5 EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On On Off 6 19...

Страница 149: ...e Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Mini...

Страница 150: ...he specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Not to Transmit the scanner will only read M...

Страница 151: ...151 6 SYMBOLOGIES Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters...

Страница 152: ...ttings 6 21 1 GS1 DataBar Omnidirectional On Off On Off 6 22 GS1 Databar Limited Default All GS1 DataBar Limited Settings 6 22 1 GS1 Databar Limited On Off On 6 21 GS1 Databar Omnidirectional 6 21 1 G...

Страница 153: ...atabar Expanded Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 M...

Страница 154: ...154 6 SYMBOLOGIES Maximum Message Length...

Страница 155: ...sage Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600...

Страница 156: ...lock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum...

Страница 157: ...157 6 SYMBOLOGIES Maximum Message Length...

Страница 158: ...Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 M...

Страница 159: ...ge amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On On Off 6 28 MicroPDF417 Default All MicroPD...

Страница 160: ...bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 Minimum Message Len...

Страница 161: ...PC EAN Version On bar code to decode GS1 Composite symbols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component Default UPC EA...

Страница 162: ...bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 2435 Minimum Default 1 Maximum Default 2435 Minimum Message Le...

Страница 163: ...3 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are ex...

Страница 164: ...164 6 SYMBOLOGIES GS1 Code Expansion Off EAN8 to EAN13 Conversion GS1 Emulation Off 6 31 TCIF Linked Code 39 TLC39 On Off 6 31 TCIF Linked Code 39 TLC39...

Страница 165: ...cro QR Code On Off 6 32 2 QR Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 7089...

Страница 166: ...ode One scan Pull the trigger one time and all appended QR Codes in the same image are decoded Swipe Pull and hold down the trigger and scan all appended QR Codes while keeping the trigger pressed The...

Страница 167: ...d was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see...

Страница 168: ...age Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 3116 Minimum Default 1 Maximum Default 311...

Страница 169: ...ted using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 I...

Страница 170: ...ge Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 M...

Страница 171: ...ge Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 3832 Minimum Default 1 Maximum Default 3832...

Страница 172: ...one time and all appended Aztec Codes in the same image are decoded Swipe Pull and hold down the trigger and scan all appended Aztec Codes while keeping the trigger pressed The scanner emits short bee...

Страница 173: ...eated using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022...

Страница 174: ...e Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833...

Страница 175: ...ne 2D postal code selection can be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off 2D Postal Codes Off 6 37 1 Single 2D Po...

Страница 176: ...176 6 SYMBOLOGIES Japanese Post On KIX Post On Planet Code On Postal 4i On Postnet On Postnet with B and B Fields On InfoMail On...

Страница 177: ...On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postal 4i and Postnet with...

Страница 178: ...lanet Code and Postal 4i On Planet Code and Intelligent Mail Bar Code Planet Code Postnet and Postal 4i On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code Postal 4i and Intelligent Ma...

Страница 179: ...Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On Planet Code Postal 4i Intelligent Mail Bar Code and Postnet On...

Страница 180: ...Code data Default Not to Transmit Transmit Check Digit Not to Transmit Check Digit 6 37 4 Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the...

Страница 181: ...causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Speci...

Страница 182: ...of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Def...

Страница 183: ...sage Length Scan the bar codes below to change the message length Refer to Message Length Description for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 M...

Страница 184: ...6 38 5 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted Default Not to Transmit Transmit Check Digit Not to Transmit Check Digit 6 38 5 Korea...

Страница 185: ...er 7 UTILITIES 7 1 To Add a Test Code I D Prefix to All Symbologies 7 2 Show Decoder Revision 7 3 Show Scan Driver Revision 7 4 Show Software Revision 7 5 Show Data Format 7 6 Test Menu 7 7 Resetting...

Страница 186: ...for all symbologies This is a temporary setting that will be removed when the unit is power cycled Add Code I D Prefix to All Symbologies Temporary 7 2 Show Decoder Revision Scan the bar code below to...

Страница 187: ...urrent software revision unit serial number and other product information for both the scan engine and base Show Software Revision 7 5 Show Data Format Scan the bar code below to show current data for...

Страница 188: ...scan engine or you ve changed some options and want to restore the scan engine to factory default settings first scan the Remove Custom Defaults bar code then scan Activate Defaults This resets the sc...

Страница 189: ...OMMANDS Chapter 8 SERIAL PROGRAMMING COMMANDS 8 1 Conventions 8 2 Menu Command Syntax 8 2 1 Serial Command Example 8 3 Trigger Commands 8 4 Setting the Custom Defaults 8 5 Resetting the Custom Default...

Страница 190: ...eld that identifies the desired menu command group For example all RS 232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desire...

Страница 191: ...he setting s The device s response uses a dash to indicate a continuous range of values A pipe separates items in a list of non continuous values Name Field Usage Optional This command returns the que...

Страница 192: ...en processed ENQ Indicates an invalid Tag or SubTag command NAK Indicates the command was good but the Data field entry was out of the allowable range for this Tag and SubTag combination e g an entry...

Страница 193: ...Enabled The Minimum Message Length MIN is set to 2 characters The Maximum Message Length MAX is set to 60 characters Default setting DFT has no value 8 3 Trigger Commands You can activate and deactiva...

Страница 194: ...5 Resetting the Custom Defaults If you want the custom default settings restored to your scan engine scan the Activate Custom Defaults bar code below This resets the scan engine to the custom default...

Страница 195: ...RMID0 232BAD9 232WRD2 14 Plug and Play Codes USB USB Keyboard PC TERMID124 15 USB Keyboard Mac TERMID125 15 USB HID TERMID131 15 USB Serial TERMID130 16 ACK NAK Mode On USBACK1 16 ACK NAK Mode Off USB...

Страница 196: ...41 20 Faroese KBDCTY83 20 Finland KBDCTY2 20 France KBDCTY3 20 Gaelic KBDCTY84 20 Germany KBDCTY4 20 Greek KBDCTY17 20 Greek 220 Latin KBDCTY64 21 Greek 220 KBDCTY61 21 Greek 319 Latin KBDCTY65 21 Gre...

Страница 197: ...44 23 Lithuania IBM KBDCTY45 23 Macedonia KBDCTY34 23 Malta KBDCTY74 24 Mongolian Cyrillic KBDCTY86 24 Norway KBDCTY9 24 Poland KBDCTY20 24 Polish 214 KBDCTY57 24 Polish Programmers KBDCTY58 24 Portug...

Страница 198: ...DCTY24 27 Ukrainian KBDCTY76 27 United Kingdom KBDCTY7 27 United Stated Dvorak KBDCTY87 28 United States Dvorak left KBDCTY88 28 United States Dvorak right KBDCTY89 28 United States International KBDC...

Страница 199: ...dows Mode Control X Mode On KBDCAS2 32 Windows Mode Prefix Suffix Off KBDCAS3 32 Turbo Mode Off KBDTMD0 33 Turbo Mode On KBDTMD1 33 Numeric Keypad Mode Off KBDNPS0 33 Numeric Keypad Mode On KBDNPS1 33...

Страница 200: ...32WRD8 37 8 Data 1 Stop Parity Mark 232WRD14 37 RS232 Receiver Time Out Range 0 300 seconds 232LPT 38 RS232 Handshaking RTS CTS Off 232CTS0 39 Flow Control No Timeout 232CTS1 39 Two Direction Flow Con...

Страница 201: ...ch Error Razz 250 Hz BEPFQ2250 47 Medium 3250 Hz BEPFQ23250 48 High 4200 Hz BEPFQ24200 48 Beeper Duration Good Read Normal Beep BEPBIP0 48 Short Beep BEPBIP1 48 LED Good Read LED Good Read Off BEPLED0...

Страница 202: ...TDEN0 55 On HSTDEN1 55 Deactivation Character 14 DC4 HSTDCH 55 Serial Trigger Mode Read Time Out 0 300 000 ms 30 000 TRGSTO 56 Presentation Mode Presentation Mode PAPPST 57 Idle Illumination Presentat...

Страница 203: ...r Quality PDF Reading Off PDFXPR0 63 Hands Free Time Out Range 0 300 000 ms 5000ms TRGPTO 63 Reread Delay in Presentation Mode Short 500ms DLYRRD500 63 Medium 750ms DLYRRD750 64 Long 1000ms DLYRRD1000...

Страница 204: ...CBOT 70 Multiple Symbols On SHOTGN1 70 Off SHOTGN0 70 No Read On SHWNRD1 71 Off SHWNRD0 71 Video Reverse Video Reverse Only VIDREV1 72 Video Reverse and Standard Bar Codes VIDREV2 72 Video Reverse Off...

Страница 205: ...ements DLYCRX 81 Character to Trigger Delay DLY_XX 81 Interfunction Delay Range 0 5000 milliseconds 5ms increments DLYFNC 82 Intermessage Delay Range 0 5000 milliseconds 5ms increments DLYMSG 83 Data...

Страница 206: ...ngs CBRDFT 105 Off CBRENA0 105 On CBRENA1 105 Codabar Start Stop Char Transmit CBRSSX1 105 Not to Transmit CBRSSX0 106 Codabar Check Character No Check Character CBRCK20 106 Validate Modulo 16 but Not...

Страница 207: ...Full ASCII Off C39ASC0 113 Full ASCII On C39ASC1 113 Code 39 Code Page Code 39 Code Page C39DCP 113 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 114 Off I25ENA0 114 On I25ENA1 11...

Страница 208: ...Code 93 Code Page C93DCP 120 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 121 Off R25ENA0 121 On R25ENA1 121 Straight 2 of 5 Industrial Message Length Minimum 1 48...

Страница 209: ...m 1 80 4 C11MIN 126 Maximum 1 80 80 C11MAX 126 Code 128 Default All Code 128 Settings 128DFT 127 Off 128ENA0 127 On 128ENA1 127 ISBT 128 Concatenation On ISBENA1 127 Off ISBENA0 128 Code 128 Message L...

Страница 210: ...D21 133 5 Digit Off UPAAD50 133 5 Digit On UPAAD51 133 UPC A Addenda Required Required UPAARQ1 133 Not Required UPAARQ0 134 UPC A Addenda Separator Off UPAADS0 134 On UPAADS1 134 UPC A EAN 13 with Ext...

Страница 211: ...UPC E0 Addenda Separator On UPEADS1 139 Off UPEADS0 139 UPC E0 Check Digit Off UPECKX0 139 On UPECKX1 139 UPC E0 Leading Zero Off UPENSX0 140 On UPENSX1 140 UPC E0 Addenda 2 Digit Addenda On UPEAD21 1...

Страница 212: ...EAN JAN 13 Addenda Required Required E13ARQ1 143 Not Required E13ARQ0 144 EAN JAN 13 Addenda Separator Off E13ADS0 144 On E13ADS1 144 ISBN Translate On E13ISB1 144 Off E13ISB0 145 EAN JAN 8 Default A...

Страница 213: ...Chars but not to Transmit MSICHK2 150 Validate 2 Type 10 Chars and Transmit MSICHK3 150 Validate Type 11 then Type 10 Char but not to Transmit MSICHK4 150 Validate Type 11 then Type 10 Char and Transm...

Страница 214: ...155 Off CBAENA0 155 On CBAENA1 155 Codablock A Message Length Minimum 1 600 1 CBAMIN 155 Maximum 1 600 600 CBAMAX 155 Codablock F Default All Codablock F Settings CBFDFT 156 Off CBFENA0 156 On CBFENA1...

Страница 215: ...site Codes On COMENA1 161 Off COMENA0 161 UPC EAN Version UPC EAN Version On COMUPC1 161 UPC EAN Version Off COMUPC0 161 GS1 Composite Codes Message Length Minimum 1 2435 1 COMMIN 162 Maximum 1 2435 2...

Страница 216: ...QRCAPP2 166 Point and Shoot QRCAPP3 167 Off QRCAPP0 167 QR Code Page QR Code Page 3 QRCDCP 167 Data Matrix Default All Data Matrix Settings IDMDFT 168 On IDMENA1 168 Off IDMENA0 168 Data Matrix Messa...

Страница 217: ...ngth Minimum 1 3832 1 AZTMIN 171 Maximum 1 3832 3832 AZTMAX 171 Aztec Append One Scan AZTAPP1 172 Swipe AZTAPP2 172 Point and Shoot AZTAPP3 172 Off AZTAPP0 173 Aztec Code Page Aztec Code Page 51 AZTDC...

Страница 218: ...Code On POSTAL16 177 Postal 4i and Intelligent Mail Bar Code On POSTAL17 177 Postal 4i and Postnet with B and B Fields On POSTAL19 177 Planet and Postnet On POSTAL12 177 Planet and Postnet with B and...

Страница 219: ...9 Planet Code Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL29 179 Planet Code Check Digit Transmit Check Digit PLNCKX1 180 Not to Transmit Check Digit PLNCKX0 180 Postn...

Страница 220: ...CMIN 183 Maximum 2 80 48 KPCMAX 183 Korea Post Check Digit Transmit Check Digit KPCCHK1 184 Not to Transmit Check Digit KPCCHK0 184 Utilities Add Code I D Prefix to All Symbologies Temporary PRECA2 BK...

Страница 221: ...221 9 TROUBLESHOOTING Chapter 9 MAINTENANCE AND TROUBLESHOOTING 9 1 Repairs 9 1 1 Inspecting Cords and Connectors 9 2 Troubleshooting...

Страница 222: ...If your scan engine is not functioning properly review the following Troubleshooting Guide to try to isolate the problem Is the power on Is the red or green aiming illumination line on If the aiming l...

Страница 223: ...l interface For example you scan 12345 and the host displays es Reprogram the scan engine with the correct Plug and Play or Terminal selection bar code The scan engine may not be programmed to output...

Страница 224: ...Linear Symbologies 2D Symbologies Postal Symbologies ASCII Conversion Chart Code Page 1252 Lower ASCII Reference Table ISO 2022 ISO 646 Character Replacements Keyboard Key References Sample Symbols Pr...

Страница 225: ...rcode Symbology ID Possible modifiers m ID HEX All Syblologies 99 Codabar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0...

Страница 226: ...e 65 Matrix 2 of 5 X0 m 6D NEC 2 of 5 X0 Y 59 Straight 2 of 5 IATA Rm 0 1 3 f 66 Straight 2 of 5 Industrial S0 f 66 MSI Mm 0 1 8 9 g 67 UPC UPC A E0 c 63 UPC A with Add On E3 c 63 UPC A with Extended...

Страница 227: ...7A Chinese Sensible Code Han Xin Code X0 H 48 Codablock A O6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Om...

Страница 228: ...HEX All Syblologies 99 Australian Post X0 A 41 British Post X0 B 42 Canadian Post X0 C 43 China Post X0 Q 51 InfoMail X0 2C Intellgent Mail Bar Code X0 M 4D Japanese Post X0 J 4A KIX Netherlands Post...

Страница 229: ...epresented in 3 different ways as shown below The CTRL X function is OS and application dependent The following table lists some commonly used Microsoft functionality This table applies to U S style k...

Страница 230: ...230 Appendix A Reference Charts...

Страница 231: ...231 Appendix A Reference Charts Lower ASCII Reference Table Note Windows Code page 1252 and lower ASCII use the same characters Lower ASCII Reference Table...

Страница 232: ...ived does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the...

Страница 233: ...233 Appendix A Reference Charts...

Страница 234: ...234 Appendix A Reference Charts Keyboard Key References 104 Key U S Style Keyboard 105 Key European Style Keyboard Key References...

Страница 235: ...235 Appendix A Reference Charts Sample Symbols UPCA EAN13 Code128 Code39 Codebar Interleaved 2 of 5 GS1 DataBar Omnidirectional PDF417 Micro PDF417 QR Code DataMatrix Sample Symbols...

Страница 236: ...236 Appendix A Reference Charts Programming Chart Numeric code table 0 1 2 3 4 5 6 Programming Chart Numeric code table...

Страница 237: ...237 Appendix A Reference Charts 7 8 9 Save Discard...

Страница 238: ...238 Appendix A Reference Charts Programming Chart Alphanumeric code table 0 1 2 3 4 5 6 Programming Chart Alphanumeric code table...

Страница 239: ...239 Appendix A Reference Charts 7 8 9 A B C D...

Страница 240: ...240 Appendix A Reference Charts E F Save Discard Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again...

Отзывы: