18
LaserLight LT 1550 Technical Manual
3.4
Testing the Remote Display
The
Laser LT
remote display provides a test menu to check the hardware of the remote display. These tests can be
accessed through the main menu (Figure 3-7).
CONFIG
SERIAL
TEST
VERS
DISPLA
INTENS
DIGIO
KEYPAD
1-7
STRTUP
On
Off
RESET
Figure 3-7. Test Menu Choices
Table 3-5. Test Menu Descriptions
TEST Menu
Parameter
Choices
Description
DISPLA
When this feature is enabled, all LEDs remain lit until a key is pressed with the exception of
the
ENTER
or
DOWN
key.
INTENS
7
1
2
3
4
5
6
This allows the user to select the degree of brightness between the values of 1-7 with 1 being
the dimmest and 7 being the brightest.
STRTUP
On
Off
When this feature is enabled, a display check is performed and the software version number
is shown at powerup.
RESET
The reset parameter resets the
Laser LT
remote display to default parameters
3.5
Keypad
By using the keypad parameter, the user is able to configure keypad operation and allows strings to be sent with
each keypad press which can be modified to comply with other manufacturers.
Press to insert a space
before the active character
EDIT
Display first 6
characters of format
ENABLE
Display and edit
active character and
ASCII value
Delete active
character
Off
On
CONFIG
SERIAL
TEST
KEYPAD
VERS
DIGIO
Scroll right in format string
Increment ASCII value of active character
Scroll left in the format string
Decrement ASCII value of active character
Figure 3-8. Keypad Menu
See Section 6.4 for how characters are displayed.
Содержание Laser LT RD-1550
Страница 2: ......
Страница 40: ...36 LaserLight LT 1550 Technical Manual 6 8 Laser LT Enclosure Dimensions 14 00 12 75 11 85 7 70 4 88 7 50 4 18...
Страница 43: ......