3
1
1..3
3 T
Te
ecch
hn
niicca
all D
Da
atta
a
Heat input nomimal ..........................................
25,2 kW
85966 Btu/h
Heat output nominal .........................................
22,7 kW
77452 Btu/h
Gas rate (maximum) :
. Natural gas (G20) 35,9 MJ/m
3
- 20 mbar .....
2,67 m
3
/h
94,29 ft
3
/h
with manifold restrictor .................................
6,1 mm diam.
. Butane (G30) 45,6 MJ/Kg - 28-30 mbar......
1,99 kg/h
. Propane (G31) 46,4 MJ/Kg - 37 mbar .........
1,96 kg/h
Main burner injectors :
. G20 ..............................................................
1,28 mm diam.
. G30 - G31.....................................................
0,74 mm diam.
Pilot injector marking G20 .................................
26
G30 - G31.......................
15
Water flow rate - raised 50°C (90°F) .................
3,2 to 6,5 l/min
0,7 to 1,43 gpm
Water flow rate - raised 25°C (45°F) .................
6,5 to 13 l/min
1,43 to 2,8 gpm
Min. water pressure selector closed ..................
0,5 bar
16,5 ft (7,5 psi)
Min. water pressure selector open ....................
1,0 bar
33,0 ft (15 psi)
Max. water pressure .........................................
10 bar
150 psi.
Electrical supply ...............................................
240 V - 50 Hz
fused 3 A
The minimum water pressure is for the correct operation of the appliance only. An additional allowance
must be made for the resistance of pipework and fittings particularly where showers and washing
machines are used. This should be equivalent to 2 m. (6,5 ft) head.
Water inlet (Compression type fittings) ..............
Right hand connection
15 mm Copper
Water outlet (Compression type fittings) ............
Left hand connection
15 mm Copper
Gas (Compression type fittings) ........................
Centre connection
15 mm Copper
Height (including flue bend) ..............................
778 mm
30,6 in
Width ................................................................
395 mm
15,5 in
Depth................................................................
270 mm
10,6 in
Weight - Cartoned .............................................
24,3 kg.
53,6 lbs.
Weight - Lift.......................................................
15 kg.
33,1 lbs.
Minimum clearances - top (above flue) .............
50 mm
2 in
- bottom (below case) .....
178 mm
7 in
- sides..............................
25 mm
1 in
- front ..............................
600 mm
24 in
Hole for the air inlet duct ..................................
102 mm diam.
4,2 in. diam.
The Britony FlexiFlue is supplied in one carton.
Compartment ventilation not required.