The Britony FlexiFlue is a room sealed, fanned balanced flue, multipoint water heater. The flue which is
100 mm (4”) diameter pipe, can be directed to the rear or to either side. The maximum recommended flue
length is 3 metres for straight application and 1,6 metres total when using a bend.
The appliance is for connection to a mains cold water supply having a minimum working pressure of 1 bar.
A permanent electrical connection is required and should be provided by use of a fused spur. The external
electrical supply should be via a double pole switch having 3 mm. contact separation in both poles. If the
appliance is installed in a bathroom the fused spur must be external to the bathroom.
When on pilot only the fan runs at “low speed” increasing to normal speed when there is a demand for hot
water. Included is a pressure switch, which operates if the fan stalls or if the flues is obstructed and a low tem-
perature sensor which will turn off the fan when the appliance is running on pilot only (fan low speed) in the
event of low air temperatures likely to cause freezing in the appliance.
N
No
otte
e ::
Gas Safety Installation and Use Reg 1984. It is the law that all gas appliances are installed by C.O.R.G.I
registered persons in accordande with the above regulations. Failure to install appliances correctly could lead
to prosecution. It is in your own interest and that of safety to ensure compliance with the law.
1
1..1
1 G
Gu
ua
arra
an
ntte
ee
e
The guarantee on this appliance is void if it is not installed in accordance with the recommendations made
herein or in a manner approved by the manufacturer.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S
T
V
W
X
mm
655
395
270
100
40
385
438
775
728
53
55
98
70
285
105
199
290
95
870
ins.
25.78
15.5
10.6
4.0
1.6
15.15
17.25
30.45
28.6
2.1
2.15
3.8
2.75
11.22
4.13
7.8
11.4
3.73
34.22
1
1..2
2 D
Diim
me
en
nssiio
on
nss
A
F
W
G
J
K
H
X
V
B
T
P
M
L
S
cable entry
C
N
E
D Ø
WATER
OUTLET
GAS WATER
INTLET