11
FACTORY PROGRAMMING DEFAULTS 9-9
Factory defaults have been split into two sections, programming and codes.
To return to factory programming defaults first enter
Engineering Mode
then
proceed as follows:-
1)
Enter 9-9
Any extension sounders will give a rapid pipping sound. The internal
keypad sounder will emit a steady tone.
2)
Enter the engineer code.
If entered correctly an accept tone will sound and the factory programming
defaults will be restored. If any error is made an error tone will sound and
the programming will not be altered. The user and engineer codes have
not changed.
If at any stage you want to default the customer codes, follow this procedure while
in engineering mode.
1)
Place the small link supplied with the spare fuses, on the memory link.
Then remove the mains and battery power.
The link is positioned left of the LEDS near the top of the pcb and is labelled
“Memory
Default”.(at which point zone 1 light will illuminate)
2)
Wait a few seconds then re-connect the battery and then the mains and
then refer to page 6 regarding initial power up.
The speaker will omit the accept tone and the factory user code defaults
will be restored.
3)
Remove the link.
( at which point zone 1 light will go out ).
GLOSSARY OF TERMS
FULL SET
This is a setting method normally used when leaving the premises. Full system armed.
NIGHT SET
This is a setting method normally used when going to bed
HOME SET
This is a setting method normally used for high security protection whilst still inside the
premises. For example an antiques cabinet etc.
ALARM
This is a zone that will trigger the panel when activated, providing the panel is set.
WALK THROUGH
This zone will be disabled during an entry period.
ISOLATE IN NIGHT SET
This simply means the zone will be disabled when the panel is NIGHT SET. For example
downstairs may be armed but upstairs may be disabled.
FACTORY
DEFAULTS
RESTORE
DEFAULT
PROGRAMMING
RESTORE
DEFAULT
CODES
GLOSSARY OF
TERMS