10
By pressing the keys 1-8 on the keypad you will select which zones you want
ISOLATED during home set.
As a key is pressed, its relevant LED on the display will toggle on or off. Any LED’s
that are ON will be ISOLATED during home set and any that are off will remain
ACTIVE.
ENGINEER ACCESS CODE
1-1
The engineer access code is programmed to 7890 by default. To change this code
(while in engineering mode):
Enter 1-1. LEDs 1, 2, 3 and 4 will illuminate.
Enter the new 4 digit code.
After each keypress one LED will go out
.
The speaker will emit an accept tone if the new code is accepted.
If the speaker emits an error tone, then your new chosen code is invalid. This
could be due to a conflict with another code. At this time your old access code is
still valid. Repeat the procedure using a different code.
ENGINEER EVENT LOG REVIEW
5 (Choices of set & unset)
The Panel stores the last alarm condition in both set and unset conditions
Select
Engineering Mode
and press 5 to gain
log
access.
You will hear a continual tone which denotes you are viewing the last set condition.
There may be no lights illuminated as there may not have been an alarm during
that time. Pressing the # key will turn off the sounder and show the last unset
period. By pressing 0 you will show the last ALARM condition that was caused in
an UNSET period (no matter how long ago that alarm was). Pressing # will bring
the sounder back on and will show the last ALARM condition in a SET state. Press
* to finish.
Pressing * will exit the log displays and return you to main engineering mode.
ENGINEER TEST OPTIONS
6 (Range 0-5)
The engineer has some test facilities available to him so he can test sounders etc.
without having to come out of engineering. These new options are accessed by
pressing 6 from within engineering mode and then selecting another option below.
Enter 0
Internal buzzer ( entry exit sound etc. )
Enter 1
Internal Sounder ( Alarm sounds from speaker / keypad )
Enter 2
External Sounder
Enter 3
External Strobe
Enter 4
L+ Terminal( even if programmed as ID- )
Enter 5
FULL LOAD ( Everything enabled )
Press * to finish and return to main engineering mode.
ENGINEER
ACCESS CODE
ENGINEER
LOG REVIEW
TOGGLE
SET & UNSET
ENGINEER
TEST OPTIONS