11 

 

TIME  OF  DAY,  YEAR, 

MONTH, DAY,  

Time of day is for normal op-
eration  of  system  and  the 
scheduling  of  the  regenera-

tion time.  The date is used in 
a  diagnostic  function  to  track 
the  last  time  the  system  re-

generated. 
 

SET HARDNESS

 

This  value  is  the  maximum 
compensated  water  hardness 
in grains per gallon of the raw 
water  supply.    It  is  used  to 

calculate the system capacity.  
If Ferrous Iron is present add 
4 gpg for every 1 ppm of Fer-

rous Iron. 
 

SET PEOPLE

 

This  value  is  the  number  of 
people living in the home.  It 
is  used  to  calculate  the 
amount  of  water  needed  for 

daily use and the reserve ca-
pacity of the system. 
 

SALT SETTING 

There  are  3  settings  to 
choose  in  the  MENU  SET-

TINGS.    These  settings  will 
determine  the  salt  dosage 
and  capacity  for  the  system.  

For SIM units choose IRON & 

MN. 
 

WATER TYPE

 

Select  WELL  /  OTHER  if  any 

Iron or Manganese is present 
or  if  the  water  source  is  not 
clean  (<  1NUT  turbidity).  

The  system  will  back  wash 
every time. 
 

REGEN TIME

 

This  setting  determines  the 
time  of  day  to  perform  a 
scheduled regeneration.

 

 

REGEN DAYS

 

This  value  is  the  number  of 

days  between  regenerations 
or  back  washes  to  clean  the 
filters. 

 

GALLONS

 

Default  value  is  OFF.    Adjust 
the  GALLONS  to  set  the  ca-

pacity.    This  will  cause  the 
unit  to  regenerate  either 
when  the  gallons  remaining 

goes  to  zero  or  the  days  be-
tween  regeneration  is  zero.  
Which ever occurs first. 

Settings

Press SETINGS key (3 SECONDS / BEEP)

VALVE MODE

SOFTENER DF

TIME OF DAY

12:01 PM

YEAR

2012

MONTH

AUGUST

DAY

21

SET HARDNESS

20 GRAINS

SET PEOPLE

4

SALT SETTING

HIGH EFFICIENCY

STANDARD

IRON & MN

WATER TYPE

MUNICIPAL

WELL / OTHER

REGEN TIME

2:00 AM

PROGRAMMING

COMPLETE

SIMTAN  UNITS  ARE  DESIGNED  TO  REMOVE  TANNINS.    YOUR  UNIT  HAS  ALREADY  BEEN  PRO-
GRAMMED BASED ON YOUR WATER CONDITIONS.  DO NOT ADJUST ANY SETTINGS BELOW OTH-

ER  THAN  TIME  OF  DAY,  YEAR,  MONTH,  DAY,  OR  REGEN  TIME.    THE  INFORMATION  BELOW  IS 
GENERAL INFORMATION ONLY. 

Programming Instructions 

Содержание 485DF SIMTAN PLUS Series

Страница 1: ...tified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system 4 Backwas...

Страница 2: ...ing water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize t...

Страница 3: ...ly lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pre...

Страница 4: ...itical Service Flow Rate 4 6 gpm 6 8 gpm 8 10 gpm 10 12 gpm Back Wash Flow Rate 2 4 gpm 4 0 gpm 5 0 gpm 7 0 gpm Shipping Weight 141 lbs 158 lbs 198 lbs 244 lbs Hardness Maximum 45 gpg Iron Maximum 15...

Страница 5: ...e Damage caused by freezing is not covered by the warranty Put the Speciality System in a place water damage is least likely to occur if a leak de velops The manufacturer will not repair or pay for wa...

Страница 6: ...d experience breakthrough for Iron Mn or Tannins To be safe choose one size larger when sizing Any oxidative pre treatment such as air or chemicals is unnecessary and should be avoided Cleaning chemic...

Страница 7: ...is decreased in the brine tank When the water in the brine tank has been drawn into the mineral tank 10 15 minutes unplug the valve 5 Turn the bypass handles to the bypass mode 6 Allow the unit to si...

Страница 8: ...alve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub...

Страница 9: ...9 Installation...

Страница 10: ...ayed on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on the bypass then open the nearest...

Страница 11: ...r if the water source is not clean 1NUT turbidity The system will back wash every time REGEN TIME This setting determines the time of day to perform a scheduled regeneration REGEN DAYS This value is t...

Страница 12: ...System operates The regeneration cy cle lasts up to 180 minutes During this time you may hear water running intermittently to About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 G...

Страница 13: ...ration Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and...

Страница 14: ...ly NUGGET or PELLET water Speciality System salt Check the salt level monthly It is important to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt dir...

Страница 15: ...the control valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriv...

Страница 16: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Страница 17: ...17...

Страница 18: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 19: ...m clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your Speciality System to freezing or to temperatures above 100 F Resin Cleaner DO NOT USE a...

Страница 20: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 21: ...21 Control Valve Exploded View...

Страница 22: ...22 Control Parts List...

Страница 23: ...44 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 60010005 OVER FLOW FITTING ASSEMBLY G 1 55010023...

Страница 24: ...24 Need to fill with something...

Страница 25: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Страница 26: ...Canature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times op...

Страница 27: ...27...

Отзывы: