Control Operation During A Power Failure
In the event of a power failure, the valve will keep track of the time and day for 48 hours.
The programmed settings are stored in a non-volatile memory and will not be lost during a
power failure. If power fails while the unit is in regeneration, the valve will finish regenera-
tion from the point it is at once power is restored. If the valve misses a scheduled regener-
ation due to a power failure, it will queue a regeneration at the next regeneration time once
power is restored.
Main Display
The main display page will pause on the Date and Time page for 5 seconds. Then it will continually scroll
through all of the system diagnostic display pages. Depending on the Valve Type some pages will not be dis-
played. To manually scroll through the diagnostics, press the down or up key. To reset the TOTAL REGENS,
TOTAL GALLONS OVER RUN TOTAL, or PEAK flow rates, press and hold the MENU until the value changes to
zero.
The brine tank is equipped with a safety float which prevents your brine tank from overfill-
ing as a result of a malfunction such as a power failure.
Safety Float
New Sounds
You may notice new sounds as your water Speciality System operates. The regeneration cy-
cle lasts up to 180 minutes. During this time, you may hear water running intermittently to
About The System
PARAMETER
DESCRIPTION
JULY/17/2012
8:30 PM
TOTAL 1,500 GAL
REMAIN 1,200 GAL
PEOPLE 2
RESERVE 150 GAL
EST. DAYS TO NEXT
REGEN 06 DAYS
LAST REGEN
9/24/12
TOTAL REGENS
10
TOTAL GALLONS
001590 GAL
OVER RUN TOTAL
0500 GAL
CURRENT 1.5 GPM
PEAK 6.5 GPM
DELAYED REGEN
OFF
REGEN TIME
2:00 AM
REFILL TIME
3:00 MIN
VALVE MODE
SOFTENER UF
The total amount of water that has exceeded the system capacity over the last 4
regenerations. When remaining goes to zero, the gallons used will be added to over run total.
The current flow rate and the peak flow rate since the last regeneration.
Advises whether a delayed regeneration has been scheduled manually or automatically.
The current setting of the valve mode.
Month, Day, Year, Time
The current calculated refill time.
The current setting for regeneration time.
Number of people in the household and the calculated reserve capacity. When remaining
reaches reserve capacity a regeneration will be scheduled.
The total amount is the system capacity when fully regenerated. The remaining is the
capacity left in the system.
The estimated number of days until the next regeneration will occur.
The date of the last regeneration.
The total number of regenerations.
The total amount of gallons treated by the system.