10
System Start-Up
1. Plug the power transformer into an ap-
proved power source. Connect the power
cord to the valve.
2. When power is supplied to the control, the
screen will display “INITIALIZING WAIT
PLEASE” while it finds the service position.
3. Manually step the valve past the BRINE
position to the BACKWASH position. If
screen is locked, press SETTINGS for 3
seconds to unlock. Press and hold the
MANUL REGEN. Key for 3 seconds. Press
any key to skip the BRINE cycle.
4. Once in the BACKWASH cycle, open the
inlet on the bypass valve slowly and allow
water to enter the unit. Allow all air to es-
cape from the unit before turning the wa-
ter on fully then allow water to run to
drain Backwash for 30 minutes to allow
the layers to settle to their appropriate
height.
5. Press any button to advance to the RINSE
position. Check the drain line flow. Allow
the water to run for 3-4 minutes or until
the water is clear.
6. Press any button to advance to the REFILL
position. Check that the valve is filling wa-
ter into the brine tank. Allow the valve to
refill for the full amount of time as dis-
played on the screen to insure a proper
brine solution for the next regeneration.
7. The valve will automatically advance to the
SERVICE position. Open the outlet valve
on the bypass, then open the nearest
treated water faucet and allow the water
to run until clear, close the tap and replace
the faucet screen.
8. Add salt into the cabinet / brine tank.
9. Program unit.
Key Pad Configuration
Start-up Instructions
SETTINGS
This function is to enter the basic set up infor-
mation required at the time of installation.
MANUAL
REGEN
This function is to initiate an immediate or
delayed manual regeneration.
DOWN /
UP
Increase or decrease the value of the settings
while in the programming mode.
DELAYED REGENERATION
Press and release the MANUAL REGEN. But-
ton to set a delayed regeneration that will
occur at the regeneration time. The main
display page will show DELAYED REGEN ON.
To cancel press and release the MANUAL RE-
GEN. Button. The main display page will
show DELAYED REGEN OFF.
IMMEDIATE REGENERATION
To start an immediate regeneration (or step
valve through each position), press and hold
the MANUAL REGEN. Button for 3 seconds
(until beeps). The valve will start an immedi-
ate regeneration. Press any key to skip to
the next cycle.
Manual Regeneration (Step / Cycle Valve)
SETTINGS
MANUAL
REGEN
UP
DOWN