1. If your hot water tank is electric, turn off the power to it to avoid damage to the element 

in the tank. 

2. If you have a private well, turn the power off to the pump and then shut off the main wa-

ter shut off valve.  If you have municipal water, simply shut off the main valve.  Go to the 
faucet, (preferably on the lowest floor of the house) turn on the cold water until all pres-

sure is relieved and the flow of water stops. 

3. Locate the Speciality System tank and brine tank close to a drain where the system will 

be installed.  The surface should be clean and level. 

4. Connect the inlet and outlet of the Speciality System using appropriate fittings.  Perform 

all plumbing according to local plumbing codes. 

• 

Use a ½” minimum pipe or tubing size for the drain line

 

• 

ON  COPPER  PLUMBING  SYSTEMS  BE  SURE  TO  INSTALL  A  GROUNDING 
WIRE BETWEEN THE INLET AND OUTLET PIPING TO MAINTAIN GROUND-
ING.

 

Any solder joints near the valve must be done before connecting any piping to the valve.  

Always leave at least 6" (152 mm) between the valve and joints when soldering pipes that 
are connected to the valve.  Failure to do this could cause damage to the valve. 
 

5. Connect the drain hose (10 ft included) to the valve and secure it with a hose clamp (also 

included).  Run the drain hose to the nearest laundry tub or drain pipe.  This can be ran 
up overhead or down along the floor.  If running the drain line more than 20 ft overhead, 

it is recommended to increase the hose size to 3/4”.  NEVER MAKE A DIRECT CONNEC-
TION INTO A WASTE DRAIN.  A PHYSICAL AIR GAP OF AT LEAST 1.5” SHOULD BE USED 

TO  AVOID  BACTERIA  AND  WASTEWATER  TRAVELLING  BACK  THROUGH  THE  DRAIN 
LINE INTO THE SPECIALITY SYSTEM. 

6. Using the Allen Key (included), place the unit in the bypass position.  Slowly turn on the 

main  water  supply.    At  the  nearest  cold  treated  water  tap  nearby  remove  the  faucet 
screen, open the faucet and let water run a few minutes or until the system is free of any 

air or foreign material resulting from the plumbing work. 

7. Make sure there are no leaks in the plumbing system before proceeding.  Close the water 

tap when water runs clean. 

8. Open the brine tank / cabinet salt lid and add water based on the chart below.  Do not 

add salt to the brine tank at this time. 

9. Proceed to start up instructions. 

Note:  The unit is not ready for service until you complete the start-up instruc-

tions. 

Installation Instructions 

Содержание 485DF SIMTAN PLUS Series

Страница 1: ...tified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system 4 Backwas...

Страница 2: ...ing water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize t...

Страница 3: ...ly lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pre...

Страница 4: ...itical Service Flow Rate 4 6 gpm 6 8 gpm 8 10 gpm 10 12 gpm Back Wash Flow Rate 2 4 gpm 4 0 gpm 5 0 gpm 7 0 gpm Shipping Weight 141 lbs 158 lbs 198 lbs 244 lbs Hardness Maximum 45 gpg Iron Maximum 15...

Страница 5: ...e Damage caused by freezing is not covered by the warranty Put the Speciality System in a place water damage is least likely to occur if a leak de velops The manufacturer will not repair or pay for wa...

Страница 6: ...d experience breakthrough for Iron Mn or Tannins To be safe choose one size larger when sizing Any oxidative pre treatment such as air or chemicals is unnecessary and should be avoided Cleaning chemic...

Страница 7: ...is decreased in the brine tank When the water in the brine tank has been drawn into the mineral tank 10 15 minutes unplug the valve 5 Turn the bypass handles to the bypass mode 6 Allow the unit to si...

Страница 8: ...alve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub...

Страница 9: ...9 Installation...

Страница 10: ...ayed on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on the bypass then open the nearest...

Страница 11: ...r if the water source is not clean 1NUT turbidity The system will back wash every time REGEN TIME This setting determines the time of day to perform a scheduled regeneration REGEN DAYS This value is t...

Страница 12: ...System operates The regeneration cy cle lasts up to 180 minutes During this time you may hear water running intermittently to About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 G...

Страница 13: ...ration Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and...

Страница 14: ...ly NUGGET or PELLET water Speciality System salt Check the salt level monthly It is important to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt dir...

Страница 15: ...the control valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriv...

Страница 16: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Страница 17: ...17...

Страница 18: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 19: ...m clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your Speciality System to freezing or to temperatures above 100 F Resin Cleaner DO NOT USE a...

Страница 20: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 21: ...21 Control Valve Exploded View...

Страница 22: ...22 Control Parts List...

Страница 23: ...44 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 60010005 OVER FLOW FITTING ASSEMBLY G 1 55010023...

Страница 24: ...24 Need to fill with something...

Страница 25: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Страница 26: ...Canature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times op...

Страница 27: ...27...

Отзывы: