Specifications 

• 

The SIMTAN PLUS needs to be used on well water where the well is greater than 140 feet deep.  

• 

CALL CUSTOMER SERVICE TO DETERMINE CORRECT MODEL. WATER TEST RESULTS REQUIRED.  

• 

Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance. 

• 

The manufacturer reserves the right to make product improvements which may  deviate  from the  specifications  and 
descriptions stated herein, without obligation to change previously manufactured products or to note the change. 

Specifications

 

SIMTANPLUS

-

150

 

SIMTANPLUS

-

200

 

SIMTANPLUS

-

250

 

SIMTANPLUS

-

300

 

Salt Used 

-

 Per Regeneration

 

9.0 lbs

 

12.0 lbs

 

15.0 lbs

 

18.0 lbs

 

Water Used 

-

 Regeneration

 

74.6 gal

 

98.9 gal

 

126.6 gal

 

153.0 gal

 

Hardness Removal 

-

 Grains

 

17,100

 

22,800

 

28,500

 

34,200

 

Advanced Exchange Media (ft3)

 

1.32ft

3

 

1.76 ft

3

 

2.20 ft

3

 

2.64 ft

3

 

Tank Size

 

10x54

 

12x52

 

13x54

 

14x65

 

Top Cone

 

Yes

 

Yes

 

Yes

 

Yes

 

Tank Jacket / Media Loaded

 

Yes

 

No

 

No

 

No

 

Brine Tank  (Inches)

 

20.3 x 37.4

 

20.3 x 37.4

 

20.3 x 37.4

 

23.0 x 40.5

 

Salt Storage Capacity 

 

350 lbs

 

350 lbs

 

350 lbs

 

420 lbs

 

Critical Service Flow Rate

 

4

-

6 gpm

 

6

-

8 gpm

 

8

-

10 gpm

 

10

-

12 gpm

 

Back Wash Flow Rate

 

2.4 gpm

 

4.0 gpm

 

5.0 gpm

 

7.0 gpm

 

Shipping Weight

 

141 lbs

 

158 lbs

 

198 lbs

 

244 lbs

 

Hardness

 

Maximum 45 gpg

 

Iron

 

Maximum 15 ppm

 

Manganese

 

Maximum 3 ppm

 

Tannins

 

Maximum 5 ppm / TOC 17 ppm

 

Ammonium

 

Maximum 4 ppm

 

pH

 

5

-

9

 

Other

 

Free Chlorine < 1 ppm, TDS < 4000 ppm

 

Regeneration Type

 

Down Flow

 

Plumbing Connections

 

Includes 3/4" 90°Elbows & 1" Straight NPT

 

Electrical Requirements

 

Input 120V 60 Hz 

-

 Output 12V 650mA

 

Water Temperature

 

Min 39  

-

 Max. 100° F

 

Water Pressure

 

Min. 20 

-

 Max. 125 psi

 

Raw Water Quality Requirements and Efficiency of Purification 

 

Parameters 

 

Influent limitations 

 

Max. Efficiency, % 

 

Hardness 

 

45 gpg 

 

97

 

Iron*

 

4 ppm 

 

98

 

Manganese

 

2 ppm 

 

98

 

TOC** (including tannins) 

 

3 ppm 

 

98

 

Ammonium 

 

4 ppm 

 

90

 

*All installations require 5 micron pre

-

filter to be installed prior to this unit. We recommend our 10” or 20” Big Value 

filter housings with a 5 micron cartridge. If ferric iron levels exceed 3ppm, or high volumes of sediment/turbidity is also 
present, a regenerating nexsand or multi

-

media filter should be installed prior to this unit. **TOC (total organic carbon) 

is used as a measure of natural organic matter content 

 

Do NOT use Pro 
Res Care or other 
media cleaners 
with these units as 
it will damage the 
media 

 

Содержание 485DF SIMTAN PLUS Series

Страница 1: ...tified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system 4 Backwas...

Страница 2: ...ing water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize t...

Страница 3: ...ly lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pre...

Страница 4: ...itical Service Flow Rate 4 6 gpm 6 8 gpm 8 10 gpm 10 12 gpm Back Wash Flow Rate 2 4 gpm 4 0 gpm 5 0 gpm 7 0 gpm Shipping Weight 141 lbs 158 lbs 198 lbs 244 lbs Hardness Maximum 45 gpg Iron Maximum 15...

Страница 5: ...e Damage caused by freezing is not covered by the warranty Put the Speciality System in a place water damage is least likely to occur if a leak de velops The manufacturer will not repair or pay for wa...

Страница 6: ...d experience breakthrough for Iron Mn or Tannins To be safe choose one size larger when sizing Any oxidative pre treatment such as air or chemicals is unnecessary and should be avoided Cleaning chemic...

Страница 7: ...is decreased in the brine tank When the water in the brine tank has been drawn into the mineral tank 10 15 minutes unplug the valve 5 Turn the bypass handles to the bypass mode 6 Allow the unit to si...

Страница 8: ...alve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub...

Страница 9: ...9 Installation...

Страница 10: ...ayed on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on the bypass then open the nearest...

Страница 11: ...r if the water source is not clean 1NUT turbidity The system will back wash every time REGEN TIME This setting determines the time of day to perform a scheduled regeneration REGEN DAYS This value is t...

Страница 12: ...System operates The regeneration cy cle lasts up to 180 minutes During this time you may hear water running intermittently to About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 G...

Страница 13: ...ration Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and...

Страница 14: ...ly NUGGET or PELLET water Speciality System salt Check the salt level monthly It is important to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt dir...

Страница 15: ...the control valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriv...

Страница 16: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Страница 17: ...17...

Страница 18: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 19: ...m clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your Speciality System to freezing or to temperatures above 100 F Resin Cleaner DO NOT USE a...

Страница 20: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 21: ...21 Control Valve Exploded View...

Страница 22: ...22 Control Parts List...

Страница 23: ...44 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 60010005 OVER FLOW FITTING ASSEMBLY G 1 55010023...

Страница 24: ...24 Need to fill with something...

Страница 25: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Страница 26: ...Canature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times op...

Страница 27: ...27...

Отзывы: