Diagnostic Messages
17
THE CANADIAN SPA COMPANY OWNERS MANUAL
Heater temp limit“Overheat” - The
spa has shut down. On some systems,
an alarm may sound. One of the sensors
has detected 118°F (approximately 47.8°C)
at the heater.
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. Once
the heater has cooled, reset by pushing
any button. If spa does not reset, shut off
the power to the spa and call your dealer
or service organisation.
“Overheat” - The spa has shut
down. One of the sensors has
detected that the spa water is
110°F (approximately 43.3°C).
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. At
107°F (approximately 41.7°C), the spa
should automatically reset. If spa does not
reset, shut off the power to the spa and
call your dealer or service organisation.
“Ice” - Potential freeze condition detected.
No action required. The pumps and the
blower will automatically activate regardless
of spa status.
Spa is shut down. The sensor that is
plugged into the Sensor “A” jack is not
working.
If the problem persists, contact your dealer
or service organisation. (May appear
temporarily in an overheat situation and
disappear when the heater cools.)
Spa is shut down. The sensor that is
plugged into the Sensor “B” jack is not
working.
If the problem persists, contact your dealer
or service organisation. (May appear
temporarily in an overheat situation and
disappear when the heater cools.)
Sensors are out of balance. If this is
alternating with the temperature, it may just
be a temporary condition. If the display
shows only this message (periodically
blinking), the spa is shut down.
If the problem persists, contact your dealer
or service organisation.
A substantial difference between the
temperature sensors was detected. This
could indicate a flow problem.
Check water level in spa. Refill if necessary.
If the water level is okay, make sure the
pumps have been primed.
Press any button to reset.
Persistent low flow problems.
Heater is shut down, but other spa
functions continue to run normally.
Follow action required for above message.
Heating capacity of the spa will not reset
automatically; you may press any button to
reset.
Message
Meaning
Action required
owners stitched 21/1/10 3:40 pm Page 19
Содержание EL
Страница 13: ...GS VS501 11 owners stitched 21 1 10 3 40 pm Page 13 ...
Страница 14: ...Diagnostic Messages 12 THE CANADIAN SPA COMPANY OWNERS MANUAL owners stitched 21 1 10 3 40 pm Page 14 ...
Страница 57: ...Hifestellung 18 Bedienungsanleitung owners stitched 21 1 10 3 41 pm Page 57 ...
Страница 59: ...Notes 20 THE CANADIAN SPA COMPANY OWNERS MANUAL owners stitched 21 1 10 3 41 pm Page 59 ...